Construction Material Nominal Size Inner Conductor BC/CCS Φ0.81mm Insulation FPE Φ3.66mm 1 st Al Foil Bonded AL FOIL 2 nd Braiding AL/ BC 60% Coverage Outer Sheath PVC/PE Φ6.10mm Power cable Material Nominal Size Inner Conductor BC/CCS 7*Φ0.38mm Insulation PVC Black,Red Φ2.3
Superlink Cable Co. [2018-07-04 14:16:45 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ0.81mm Insulation FPE Φ3.66mm 1 st Al Foil Bonded AL FOIL 2 nd Braiding AL/ BC 60% Coverage 3 rd Al Foil AL FOIL 4 th Braiding AL/BC 40% Coverage Outer Sheath PVC/PE Φ6.73mm
Superlink Cable Co. [2018-07-04 14:15:32 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ0.81mm Insulation FPE Φ3.66mm 1 st Al Foil Bonded AL FOIL 2 nd Braiding AL/ BC 60% Coverage 3 rd Al Foil AL FOIL 4 th Braiding AL/BC 40% Coverage Anticorrosive Adhesive Jelly Outer Sheath PVC/PE Φ6.73mm
Superlink Cable Co. [2018-07-04 14:14:37 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.63mm Insulation FPE Φ7.11mm 1 st Al Foil Bonded AL FOIL 2 nd Braiding AL/ BC 60% Coverage 3 rd Al Foil AL FOIL Outer Sheath PVC/PE Φ10.16mm
Superlink Cable Co. [2018-07-04 14:13:45 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.63mm Insulation FPE Φ7.11mm 1 st Al Foil Bonded AL FOIL 2 nd Braiding AL/ BC 60% Coverage 3 rd Al Foil AL FOIL Outer Sheath PVC/PE Φ10.16mm Messenger Galvanized steel Φ1.83mm
Superlink Cable Co. [2018-07-04 14:12:52 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.63mm Insulation FPE Φ7.11mm 1 st Al Foil Bonded AL FOIL 2 nd Braiding AL/ BC 60% Coverage 3 rd Al Foil AL FOIL Anticorrosive Adhesive Jelly Outer Sheath PVC/PE Φ10.16mm
Superlink Cable Co. [2018-07-04 14:12:00 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.63mm Insulation FPE Φ7.11mm 1 st Al Foil Bonded AL FOIL 2 nd Braiding AL/ BC 60% Coverage 3 rd Al Foil AL FOIL Anticorrosive Adhesive Jelly Outer Sheath PVC/PE Φ10.16mm Messenger Galvanized steel Φ1.83mm
Superlink Cable Co. [2018-07-04 14:11:10 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.63mm Insulation FPE Φ7.11mm 1 st Al Foil Bonded AL FOIL 2 nd Braiding AL/ BC 60% Coverage Outer Sheath PVC/PE Φ10.03mm
Superlink Cable Co. [2018-07-04 14:10:11 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.63mm Insulation FPE Φ7.11mm 1 st Al Foil Bonded AL FOIL 2 nd Braiding AL/ BC 60% Coverage Outer Sheath PVC/PE Φ10.03mm Messenger Galvanized steel Φ1.83mm
Superlink Cable Co. [2018-07-04 14:09:19 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.63mm Insulation FPE Φ7.11mm 1 st Al Foil Bonded AL FOIL 2 nd Braiding AL/ BC 60% Coverage Anticorrosive Adhesive Jelly Outer Sheath PVC/PE Φ10.03mm
Superlink Cable Co. [2018-07-04 14:08:22 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.63mm Insulation FPE Φ7.11mm 1 st Al Foil Bonded AL FOIL 2 nd Braiding AL/ BC 60% Coverage Anticorrosive Adhesive Jelly Outer Sheath PVC/PE Φ10.03mm Messenger Galvanized steel Φ1.83mm
Superlink Cable Co. [2018-07-04 14:07:24 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.63mm Insulation FPE Φ7.11mm 1 st Al Foil Bonded AL FOIL 2 nd Braiding AL/ BC 60% Coverage 3 rd Al Foil AL FOIL 4 th Braiding AL/BC 40% Coverage Outer Sheath PVC/PE Φ10.34mm
Superlink Cable Co. [2018-07-04 14:06:25 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.63mm Insulation FPE Φ7.11mm 1 st Al Foil Bonded AL FOIL 2 nd Braiding AL/ BC 60% Coverage 3 rd Al Foil AL FOIL 4 th Braiding AL/BC 40% Coverage Outer Sheath PVC/PE Φ10.34mm Messenger Galvanized steel Φ1.83mm
Superlink Cable Co. [2018-07-04 14:05:25 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.63mm Insulation FPE Φ7.11mm 1 st Al Foil Bonded AL FOIL 2 nd Braiding AL/ BC 60% Coverage 3 rd Al Foil AL FOIL 4 th Braiding AL/BC 40% Coverage Anticorrosive Adhesive Jelly Outer Sheath PVC/PE Φ10.34mm
Superlink Cable Co. [2018-07-04 14:04:11 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.63mm Insulation FPE Φ7.11mm 1 st Al Foil Bonded AL FOIL 2 nd Braiding AL/ BC 60% Coverage 3 rd Al Foil AL FOIL 4 th Braiding AL/BC 40% Coverage Anticorrosive Adhesive Jelly Outer Sheath PVC/PE Φ10.34mm Messenger Galv
Superlink Cable Co. [2018-07-04 14:02:46 ]
Construction Material Nominal Size Inner Conductor BCCCS Φ1.02mm Insulation FPE Φ4.57mm 1 st Al Foil Bonded AL FOIL 2 nd Braiding AL/ BC 60% Coverage 3 rd Al Foil AL FOIL Outer Sheath PVC/PE Φ7.06mm
Superlink Cable Co. [2018-07-04 14:01:37 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.02mm Insulation FPE Φ4.57mm 1 st Al Foil Bonded AL FOIL 2 nd Braiding AL/ BC 60% Coverage 3 rd Al Foil AL FOIL Outer Sheath PVC/PE Φ7.06mm Messenger Galvanized steel Φ1.30mm
Superlink Cable Co. [2018-07-04 14:00:40 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.02mm Insulation FPE Φ4.57mm 1 st Al Foil Bonded AL FOIL 2 nd Braiding AL/ BC 60% Coverage 3 rd Al Foil AL FOIL Anticorrosive Adhesive Jelly Outer Sheath PVC/PE Φ7.06mm
Superlink Cable Co. [2018-07-04 13:59:46 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.02mm Insulation FPE Φ4.57mm 1 st Al Foil Bonded AL FOIL 2 nd Braiding AL/ BC 60% Coverage 3 rd Al Foil AL FOIL Anticorrosive Adhesive Jelly Outer Sheath PVC/PE Φ7.06mm Messenger Galvanized steel Φ1.30mm
Superlink Cable Co. [2018-07-04 13:58:39 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.02mm Insulation FPE Φ4.57mm 1 st Al Foil Bonded AL FOIL 2 nd Braiding AL/ BC 60% Coverage Outer Sheath PVC/PE Φ6.91mm
Superlink Cable Co. [2018-07-04 13:57:42 ]