Construction Material Nominal Size Inner Conductor BC/CCS Φ1.63mm Insulation FPE Φ7.11mm 1stAl Foil Bonded AL FOIL 2nd Braiding AL/ BC 60% Coverage 3rdAl Foil AL FOIL Outer Sheath PVC/PE Φ10.16mm Messenger Galvanized steel Φ1.83mm ...
Superlink Cable Co. [Electrical Equipment & Supplies] [Wires, Cables & Cable Assemblies] [2018-07-04 14:12:52 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.63mm Insulation FPE Φ7.11mm 1stAl Foil Bonded AL FOIL 2nd Braiding AL/ BC 60% Coverage 3rdAl Foil AL FOIL Anticorrosive Adhesive Jelly Outer Sheath PVC/PE Φ10.16mm ...
Superlink Cable Co. [Electrical Equipment & Supplies] [Wires, Cables & Cable Assemblies] [2018-07-04 14:12:00 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.63mm Insulation FPE Φ7.11mm 1stAl Foil Bonded AL FOIL 2nd Braiding AL/ BC 60% Coverage 3rdAl Foil AL FOIL Anticorrosive Adhesive Jelly Outer Sheath PVC/PE Φ10.16mm Messenger Galvanized steel Φ1.83mm ...
Superlink Cable Co. [Electrical Equipment & Supplies] [Wires, Cables & Cable Assemblies] [2018-07-04 14:11:10 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.63mm Insulation FPE Φ7.11mm 1stAl Foil Bonded AL FOIL 2nd Braiding AL/ BC 60% Coverage Outer Sheath PVC/PE Φ10.03mm ...
Superlink Cable Co. [Electrical Equipment & Supplies] [Wires, Cables & Cable Assemblies] [2018-07-04 14:10:11 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.63mm Insulation FPE Φ7.11mm 1stAl Foil Bonded AL FOIL 2nd Braiding AL/ BC 60% Coverage Outer Sheath PVC/PE Φ10.03mm Messenger Galvanized steel Φ1.83mm ...
Superlink Cable Co. [Electrical Equipment & Supplies] [Wires, Cables & Cable Assemblies] [2018-07-04 14:09:19 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.63mm Insulation FPE Φ7.11mm 1stAl Foil Bonded AL FOIL 2nd Braiding AL/ BC 60% Coverage Anticorrosive Adhesive Jelly Outer Sheath PVC/PE Φ10.03mm ...
Superlink Cable Co. [Electrical Equipment & Supplies] [Wires, Cables & Cable Assemblies] [2018-07-04 14:08:22 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.63mm Insulation FPE Φ7.11mm 1stAl Foil Bonded AL FOIL 2nd Braiding AL/ BC 60% Coverage Anticorrosive Adhesive Jelly Outer Sheath PVC/PE Φ10.03mm Messenger Galvanized steel Φ1.83mm ...
Superlink Cable Co. [Electrical Equipment & Supplies] [Wires, Cables & Cable Assemblies] [2018-07-04 14:07:24 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.63mm Insulation FPE Φ7.11mm 1stAl Foil Bonded AL FOIL 2nd Braiding AL/ BC 60% Coverage 3rdAl Foil AL FOIL 4thBraiding AL/BC 40% Coverage Outer Sheath PVC/PE Φ10.34mm ...
Superlink Cable Co. [Electrical Equipment & Supplies] [Wires, Cables & Cable Assemblies] [2018-07-04 14:06:25 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.63mm Insulation FPE Φ7.11mm 1stAl Foil Bonded AL FOIL 2nd Braiding AL/ BC 60% Coverage 3rdAl Foil AL FOIL 4thBraiding AL/BC 40% Coverage Outer Sheath PVC/PE Φ10.34mm Messenger Galvanized steel Φ1.83mm ...
Superlink Cable Co. [Electrical Equipment & Supplies] [Wires, Cables & Cable Assemblies] [2018-07-04 14:05:25 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.63mm Insulation FPE Φ7.11mm 1stAl Foil Bonded AL FOIL 2nd Braiding AL/ BC 60% Coverage 3rdAl Foil AL FOIL 4thBraiding AL/BC 40% Coverage Anticorrosive Adhesive Jelly Outer Sheath PVC/PE Φ10.34mm ...
Superlink Cable Co. [Electrical Equipment & Supplies] [Wires, Cables & Cable Assemblies] [2018-07-04 14:04:11 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.63mm Insulation FPE Φ7.11mm 1stAl Foil Bonded AL FOIL 2nd Braiding AL/ BC 60% Coverage 3rdAl Foil AL FOIL 4thBraiding AL/BC 40% Coverage Anticorrosive Adhesive Jelly Outer Sheath PVC/PE Φ10.34mm Messenger ...
Superlink Cable Co. [Electrical Equipment & Supplies] [Wires, Cables & Cable Assemblies] [2018-07-04 14:02:46 ]
Construction Material Nominal Size Inner Conductor BCCCS Φ1.02mm Insulation FPE Φ4.57mm 1stAl Foil Bonded AL FOIL 2nd Braiding AL/ BC 60% Coverage 3rdAl Foil AL FOIL Outer Sheath PVC/PE Φ7.06mm ...
Superlink Cable Co. [Electrical Equipment & Supplies] [Wires, Cables & Cable Assemblies] [2018-07-04 14:01:37 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.02mm Insulation FPE Φ4.57mm 1stAl Foil Bonded AL FOIL 2nd Braiding AL/ BC 60% Coverage 3rdAl Foil AL FOIL Outer Sheath PVC/PE Φ7.06mm Messenger Galvanized steel Φ1.30mm ...
Superlink Cable Co. [Electrical Equipment & Supplies] [Wires, Cables & Cable Assemblies] [2018-07-04 14:00:40 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.02mm Insulation FPE Φ4.57mm 1stAl Foil Bonded AL FOIL 2nd Braiding AL/ BC 60% Coverage 3rdAl Foil AL FOIL Anticorrosive Adhesive Jelly Outer Sheath PVC/PE Φ7.06mm ...
Superlink Cable Co. [Electrical Equipment & Supplies] [Wires, Cables & Cable Assemblies] [2018-07-04 13:59:46 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.02mm Insulation FPE Φ4.57mm 1stAl Foil Bonded AL FOIL 2nd Braiding AL/ BC 60% Coverage 3rdAl Foil AL FOIL Anticorrosive Adhesive Jelly Outer Sheath PVC/PE Φ7.06mm Messenger Galvanized steel Φ1.30mm ...
Superlink Cable Co. [Electrical Equipment & Supplies] [Wires, Cables & Cable Assemblies] [2018-07-04 13:58:39 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.02mm Insulation FPE Φ4.57mm 1stAl Foil Bonded AL FOIL 2nd Braiding AL/ BC 60% Coverage Outer Sheath PVC/PE Φ6.91mm ...
Superlink Cable Co. [Electrical Equipment & Supplies] [Wires, Cables & Cable Assemblies] [2018-07-04 13:57:42 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.02mm Insulation FPE Φ4.57mm 1stAl Foil Bonded AL FOIL 2nd Braiding AL/ BC 60% Coverage Outer Sheath PVC/PE Φ6.91mm Messenger Galvanized steel Φ1.30mm ...
Superlink Cable Co. [Electrical Equipment & Supplies] [Wires, Cables & Cable Assemblies] [2018-07-04 13:56:37 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.02mm Insulation FPE Φ4.57mm 1stAl Foil Bonded AL FOIL 2nd Braiding AL/ BC 60% Coverage Anticorrosive Adhesive Jelly Outer Sheath PVC/PE Φ6.91mm ...
Superlink Cable Co. [Electrical Equipment & Supplies] [Wires, Cables & Cable Assemblies] [2018-07-04 13:54:58 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.02mm Insulation FPE Φ4.57mm 1stAl Foil Bonded AL FOIL 2nd Braiding AL/ BC 60% Coverage Anticorrosive Adhesive Jelly Outer Sheath PVC/PE Φ6.91mm Messenger Galvanized steel Φ1.30mm ...
Superlink Cable Co. [Electrical Equipment & Supplies] [Wires, Cables & Cable Assemblies] [2018-07-04 13:32:21 ]
Construction Material Nominal Size Inner Conductor BC/CCS Φ1.02mm Insulation FPE Φ4.57mm 1stAl Foil Bonded AL FOIL 2nd Braiding AL/ BC 60% Coverage 3rdAl Foil AL FOIL 4thBraiding AL/BC 40% Coverage Outer Sheath PVC/PE Φ7.54mm ...
Superlink Cable Co. [Electrical Equipment & Supplies] [Wires, Cables & Cable Assemblies] [2018-07-04 13:31:25 ]