Applications thickness of rock, water resistivity, clay content, permeability, resistivity of erosion belt, lithology and oil stratum thickness. Specifications The spacing of the four electrodes is up to you Measuring parameters SP, NR, LR and IP Measuring range 0 to 10KΩm Meas
Zhuhai Dshing Import&Export Co.,ltd [2014-08-19 21:03:24 ]
Specifications Dimensions ᆭᅰ40ᄀ1330mm (A0.9M0.1N),ᆭᅰ40ᄀ2332mm (A1.6M0.4N) Pressurization less than 15Mpa Measurable parameters SP, NR, and LR
Zhuhai Dshing Import&Export Co.,ltd [2014-08-19 21:02:57 ]
Specifications Flux unit tons per hours, impulse scale. Dimensions ф51×1300mm; ф50×1270mm (3000m) Pressurization ≤15 MPa; ≤30 MPa (3000m) Work temperature -10℃ to 85℃ Weight 8.7 kg; 9.5kg (3000m)
Zhuhai Dshing Import&Export Co.,ltd [2014-08-19 21:02:35 ]
Specifications Measurement parameter nature gamma Dimensions ф40mm×870mm;ф45mm×870mm (3000m) Pressurization ≤ 20Mpa Digital transmission 8 bits serial output Operating temperature 0℃ to +60 ℃ Range more than 30Kev Weight 5.7 kg; 6.8 kg (3000m) Scintillator NaI(Tl) 、
Zhuhai Dshing Import&Export Co.,ltd [2014-08-19 21:01:28 ]
Specifications Measuring parameters N-N, natural gamma Neutron activated source 241Am-9Be, 1Ci Counting range 0 to 10000cp Proportional counter 39He Natural gamma Scintillating material Nal(T1), Φ23×60m Photomultiplier tube type GDB23 Measuring range >30Kev gamma ray Count
Zhuhai Dshing Import&Export Co.,ltd [2014-08-19 21:01:09 ]
Application I n research of uranium ore, divide the strata, and tell the oil stratum from the water zone. Specifications Measuring range 0.3Mev to 3Mev full differential spectrum Resolution standard-source C137s(0.66Mev) ≤15% Time count range 4″,12″,20″,28″,36 by manua
Zhuhai Dshing Import&Export Co.,ltd [2014-08-19 21:00:47 ]
Technical Data Impedance 50Ω Frequency range 0~3 GHz Insulation resistance ≥5000MΩ Withstanding voltage 1000V Temperature range -55 °C ~ +165 °C Weight 4g Durability (matings) >500 Material Data Piece Part Base Material Plating Center contact Phosphor Bronze Gold plating (N
Cmpter Electronics Co., Limited [2014-08-19 07:41:50 ]
Technical Data Impedance 50Ω Frequency range 0~6 GHz Insulation resistance ≥5000MΩ Withstanding voltage 1000 V Cable entry center contact Soldered Cable entry outer contact Crimped Temperature range -65 °C ~ +165 °C Weight 30g Durability (matings) >500 Material Data Piece P
Cmpter Electronics Co., Limited [2014-08-19 07:39:53 ]
Technical Data Impedance 50Ω Frequency range 0~4 GHz Insulation resistance ≥5000MΩ Withstanding voltage 1000V Temperature range -65 °C ~ +165 °C Weight 12g Durability (matings) >500 Material Data Piece Part Base Material Plating Center contact Phosphor Bronze Gold Plated Bo
Cmpter Electronics Co., Limited [2014-08-19 07:37:43 ]
Technical Data Impedance 50Ω Frequency range 0~1 GHz Insulation resistance ≥5000MΩ Operating voltage ≤500 Volts Temperature range -55 °C ~ +165 °C Weight 21.5g Durability (matings) >500 Material Data Piece Part Base Material Plating Center contact Brass & Phosphor Bronze
Cmpter Electronics Co., Limited [2014-08-19 07:36:24 ]
Technical Data Impedance 50Ω Frequency range 0~3 GHz Insulation resistance ≥5000MΩ Withstanding voltage 2500 V Cable entry center contact Plugged Cable entry outer contact Clamped Temperature range -65 °C ~ +165 °C Weight 80g Durability (matings) >500 Material Data Piece Pa
Cmpter Electronics Co., Limited [2014-08-19 07:34:31 ]
Technical Data Impedance 50Ω Frequency range 0~3 GHz Insulation resistance ≥5000MΩ Withstanding voltage 2500 V Cable entry center contact Plugged Cable entry outer contact Clamped Temperature range -55 °C ~ +165 °C Weight 126g Durability (matings) >500 Material Data Piece P
Cmpter Electronics Co., Limited [2014-08-19 07:33:10 ]
Technical Data Impedance 50Ω Frequency range 0~3 GHz Insulation resistance ≥5000MΩ Withstanding voltage 2500 V Cable entry center contact Plugged Cable entry outer contact Clamped Temperature range -55 °C ~ +165 °C Weight 133g Durability (matings) >500
Cmpter Electronics Co., Limited [2014-08-19 07:32:00 ]
Application U sed for big-bore logging Specifications Measuring range 75mm to 700mm Output signal 0 to 9V DC voltage Sensitivity 2 mm Dimensions φ40×1620mm, φ50×1324mm (3000m) Pressurization ≤ 20Mpa, ≤ 30Mpa (3000m) Weight 6.5kg, 7.2kg (3000m)
Zhuhai Dshing Import&Export Co.,ltd [2014-08-19 05:16:44 ]
Applications check the integrity of well and provide additional information to help. Specifications Measuring range 40mm to 300mm Output signals 0 to 9V DC voltage Sensitivity 1mm Work temperature -10℃ to 60℃ Dimensions φ40×1320mm, φ50×1324mm (3000m) Pressurization ≤ 20
Zhuhai Dshing Import&Export Co.,ltd [2014-08-19 05:16:18 ]
Application seeking for magnetic iron ores Specifications : Measuring range 1 to 10000×10-4 SI Output signal 0 to 9V DC voltage Scale accuracy ≤5% Stability error ≤10% Work temperature -10℃ to 60℃ Dimensions φ45×1200mm,φ48.5×1377mm (3000m) Pressurization ≤ 20Mpa,
Zhuhai Dshing Import&Export Co.,ltd [2014-08-19 05:16:00 ]
Application determines the resistivity of rock strata. Specifications : Measuring range 0 to 10KΩm Output signal 0 to 9V DC Work temperature -10℃ to 60℃ Dimensions ф40×1416mm, ф50×1416mm (3000m) Pressurization ≤ 20Mpa, ≤ 30Mpa (3000m) Weight 6.6kg,7.2kg (3000m)
Zhuhai Dshing Import&Export Co.,ltd [2014-08-19 05:15:43 ]
Applications locate the aquifer bed or thermal spring in the geothermal survey; search for petroleum and gases Specifications : Measuring range -10℃ to 100℃ Measurement sensitivity ≤0.05℃ Temperature-sensing time ≤1s Temp-measuring derivation ≤5% Dimensions φ40×13
Zhuhai Dshing Import&Export Co.,ltd [2014-08-19 05:15:26 ]
Advantages 1 It is used for exploring the dry borehole. 2 The method that compensated density can divide the strata, determine. 3 the porosity of rock and density of volume. Naturalγis applied to identify lithology, locate the strata, estimate the sludge 4 content, tell the rock
Zhuhai Dshing Import&Export Co.,ltd [2014-08-19 05:15:10 ]
F unction : It is a non-oriented measurement of single-source double-receiver Determination including lithology, strata porosity, gas-contained strata, and fault detection. use any other log resources, can ascertain the degree of moisture content of strata, and if execute the a
Zhuhai Dshing Import&Export Co.,ltd [2014-08-19 05:14:51 ]