Frequency : 60Hz, 50Hz Primary voltage : 22900(Y) / 12600V Secondary voltage : 230/115, 460/230V TAP Voltage : 14.4 - 13.8 - 13.2 - R12.6 -12.0KV(230/115V) TAP Voltage : 13.8 - 13.2 - R12.6 - 12.0 - 11.4KV(460/230V) ...
Kp Electric Co., Ltd. [Electrical Equipment & Supplies] [Transformers]
- maximum ambient temperature 40?C Max 10) Ambient Temperature - custom made designs are catered for upon request 9) Optional - air cool 8) Cooling - Class A, Class B, Class F & Class H 7) Insulation Class - flexible wires - soldering pins - chrome plated high grade mild steel ...
Success Electronics & Transformer Manufacturer Sdn Bhd [Electrical Equipment & Supplies] [Transformers]
Office and Factory Plot No. R-603, T.T.C Industrial Area, Rabale, P.O. Ghansoli, Navi Mumbai 400 701, Maharashtra India Tel : 91-22-2769 1021 91-22-2769 1887 91-22-2760 1262 Fax : 91-22-2760 1263 Dispatch Hi-Tech has in house facility to stuff 20 or 40 feet containers. ...
HI-TECH SWITCHGEARS PVT. LTD [Electrical Equipment & Supplies] [Transformers]
Coil Number:Other Coil Structure:Other Phase:Single Usage:Electronic Place of Origin:United Arab Emirates LNB is available In HD quality with one line out means T1, T2, T4 AND T8 Plus we have quatro LNB for central satellite system ...
al zaidi electronic [Electrical Equipment & Supplies] [Transformers]
Technical Characteristics Type Tested Assembly (7 Type Tests) Compliance with Standards IEC 60439-1 Arc Fault Withstand current 50 kA (IEC 1641:1996) Rated service voltage Ue up to 690 V Rated insulation voltage Ui up to 1000 V Rated impulse withstand voltage Uimp 8 kV Rated ...
Powertech Switchgear Industries LLC [Electrical Equipment & Supplies] [Transformers]
Technical data Ignition system MKZ 100 (Part No. 0.096 600 017) Operating voltage 230 V (-15 % + 10 %) 50/60 Hz Primary Currrent 0.22 A Output Connection 50 VA Primary 2 x flat plug 2.8 mm Secondary 2 x 4 mm drop in pins Ignition voltage 2 x 7.5 kV Ignition frequency 25/30 Hz ...
Linear Systems [Electrical Equipment & Supplies] [Transformers]
Varnish Impregnated Dry Type Transformer Varnish Dry Type transformers are manufactured upto 1 MVA, 11 KV they are available in both class F class H insulation. Voltage Taps Standards units are provided with 4 tappings. Two 2.5% above normal and two 2.5% below normal. ( + 2 x ...
L D POWER TRANSFORMERS PVT LTD [Electrical Equipment & Supplies] [Transformers]
KIRLOSKAR/VIVEKANAND / ARGO make transformers are widely used by electricity boards, power distribution houses, textile mills, paper plants, chemical plants, pharmaceutical industries, automobile industries, railways, public sector under takings & various other industries, ...
ALAKH ENTERPRiSES [Electrical Equipment & Supplies] [Transformers]
Output: 20W at 50Hz Primary: 10K or 14K Ohms Secondary: 4, 8, 16 Ohms FR(+-2dB) 30-50,000Hz ...
Tube technologies [Electrical Equipment & Supplies] [Transformers]
with rated voltage up to 36 KV, single phase or three phase, 50 or 60 Hz. dry type or oil immersed hermetically sealed or conservator type. ELECTRICAL CHARACTERISTIC at 75oC, 50 Hz, 3 Phase, 400 VoltSPLN Standard Type KVA Losses in Watt Imp % Vector Group No Load Load T25N50 25 ...
asata [Electrical Equipment & Supplies] [Transformers]
TFT-LCD (Thin Film Transistor-Liquid Crystal Display) consists of on LCD panel composed of the screen, the backlight, a light source to transmit light onto LCD, and the Inverter high voltage to drive the backlight; a high voltage transformer to modulate frequency and increase ...
EXA ENC [Electrical Equipment & Supplies] [Transformers]
Athlon Phenom~9600/Phenom X3~8750/Phenom X4~9950 Athlon 64 X2~3600+ /~6400+(AM2) Athlon 64 FX-51/53/55/57/60/62 Opteron ~154 / ~256 / ~890 Dual-Core Opteron ~180 / ~290 / ~890 Second-Generation Opteron ~1222 SE/1222 Third-Generation Opteron ~1356 Sempron ~3800+. Pentium 4 ...
EVERCOOL THERMAL CO., LTD. [Electrical Equipment & Supplies] [Transformers]
Coil Number:Autotransformer Coil Structure:Toroidal Phase:Three Usage:Power Model Number:TMBA Brand Name:Alttrans Place of Origin:Russian Federation Three-phase oil transformers intended for heat treatment of concrete and soil (TMB) with the power of 80 kVA and voltage 0,4 kV ...
ALTAI TRANSFORMER PLANT OJSC [Electrical Equipment & Supplies] [Transformers]
Phase Single Frequency 50 ~ 60 Hz Rated capacity 10 ~ 333kv Voltage system H.V : 3.6kv, 12kv,24kv, and 13.2grdy/7.62kv, 24.94grdy/14.4kv L.V : 220/110v, 240/120v, 480/240v ...
DAE WOONG ELETRIC CO., LTD [Electrical Equipment & Supplies] [Transformers]
Wide bandwidth 4 Hz up to 10 kHz Rogowski type probe ensures stable measurement. Flexible current probe can be clipped around a conductor without disconnecting the conductor. Measuring in tight places as never before possible. 300 Amps type and 3000 Amps type available ...
M-System Co Ltd [Electrical Equipment & Supplies] [Transformers]
Maximize the performance of your SQL-based traffic over wide-area TCP/IP networks, and get dramatically improved application response times from your existing infrastructure.--------------------------------------------------------------------------------BoostSQLBoostSQL ...
ARC Electronics [Electrical Equipment & Supplies] [Transformers]
Great memory capacity up to 120 sets of molding data Can be online with a personal computer to set up a production information system Provides 5-injection speed control, 5-injection pressure control and 4-stage holding pressure control to meet most complicated molding ...
HWA CHIN Machinery Factory Co., Ltd. [Electrical Equipment & Supplies] [Transformers]
Name characteristic Value characteristic 1. Mains voltage, V 2E380 2. Mains frequency, Hz> 50 3. Duty cycle, %, at maximal welding current 100 4. No-load voltage, V, no more 70 5. Range of welding current control, 120-500 6. Rated operating voltage, V 40 7. Range of operating ...
JSK SIMFEROPOL MOTOR PLANT [Electrical Equipment & Supplies] [Transformers]
Standard Features No-Load Tapchanger when required Dial-Type Thermometer Secondary Spade Connectors Drain Valve or Combination Drain and Sampler Valve Pressure Relief Valve (smaller KVA Ratings) Upper Filter Press Connection NEMA Two-Hole Ground Pad Stainless Steel Nameplate ...
Sunbelt Transformer [Electrical Equipment & Supplies] [Transformers]
For GSM850 Tx & Rx 1.6x0.8x0.6 HHM1776B2 PDF:36KB 2.0x1.25x0.95 HHM1522A7 PDF:56KB HHM1523B3 PDF:56KB HHM1524B4 PDF:56KB ...
Nine Big Co., Ltd. [Electrical Equipment & Supplies] [Transformers]