Testosterone 99% High Purity Hormone Steroid Power Testosterone Base 58-22-0 Chemical name 4-Androsten-17β-ol-3-one Synonyms 17beta-Hydroxyandrost-4-en-3-one CAS 58-22-0 EINECS 200-370-5 Assay 98% min. Molecular formula C19H28O2 Packing foil bag or tin. Appearance white or off-w
Zhuzhou Yuancheng Hezhong Technology Development Co., Ltd. [2014-12-08 04:36:53 ]
Egrifta(Tesamorelin) (2mg/vial,10vial/kit) http://www steroidsgym com/ Assay 2mg/Vial, 10Vials/Kit MOQ 10Vials Price 15USD/Vial Sequence H-HIS-ALA-GLU-GLY-THR-PHE-THR-SER-ASP-VAL-SER-SER-TYR-LEU-GLU-GLY-GLN-ALA-ALA-LYS-GLU-PHE-ILE-ALA-TRP-LEU-VAL-LYS-GLY-ARG-GLY-OH Cas No. 106612
Zhuzhou Yuancheng Hezhong Technology Development Co., Ltd. [2014-12-08 03:15:45 ]
Supply all kinds of raw steroids ,anabolic bodybuilding supplements Testosterone Enanthate CAS No. 315-37-7 Content 98% Testosterone Enanthate powder Appearance off-white crystalline powder Origin China Storage shading, confined preservation. Testosterone Enanthate is a steroid
Shenzhen Shijingu raws Co.Ltd. [2014-12-07 21:12:06 ]
anabolic bodybuilding supplements Testosterone acetate zara at pharmade dot com Testosterone acetate CAS 1045-69-8 Category Pharmaceutical raw materials and intermediates Properties white or white crystalline powder Content 99% Packaging 1kg aluminum foil bag For more details, pl
Shenzhen Shijingu raws Co.Ltd. [2014-12-07 19:45:02 ]
1.1Application The VLF Very low frequency Tester is applied in power cable and generator insulation test in power system 1.2Technical index 1 Max voltage output refer to table 1 2 Output frequency 0.1Hz, 0.05Hz, 0.02Hz 3 Measurement error < 3%RDG+0.3%FS 4. Positive and negative v
重庆格纳迪机电设备有限公司 [2014-12-07 08:10:34 ]
1.1 Functions 1. DC voltage relay test 2. DC current relay test 3. AC voltage relay test 4. AC current relay test 5. High current injection 6 Time counter in relay test 1.2Technique index 1. DC voltage output 0~350V continuous adjustable, output capacity 960VA 2. AC voltage outpu
重庆格纳迪机电设备有限公司 [2014-12-07 08:08:46 ]
1.1Application GDJB-PC is applied to test the relay unit in relay protection system. At the same time GDJB-PC could be considered as a universal three phase AC/DC voltage source or current source. 1.2Functions 1 ) AC current and voltage based protection relay unit test 2) DC curr
重庆格纳迪机电设备有限公司 [2014-12-07 08:07:46 ]
1.1 Application GDDW-grounding resistance tester is applied to measure the grounding resistance in power station or generator station with non-power frequency. All test results could be printed by micro printer 1.2Technique index 1.Measurementscope 0~150Ω(includingimpedanceofc
重庆格纳迪机电设备有限公司 [2014-12-07 08:05:12 ]
1.1Application The tester GD2571 is applied to measure the earth resistance of equipments and conductive and resistance low resistance circuit in power system 1.2Technical parameters 1 Measurement range and error 0~1.999ohm <3%RDG+1D Resolution 0.001ohm 2~19.99ohm <1.5%RDG+1D Res
重庆格纳迪机电设备有限公司 [2014-12-07 08:04:30 ]
Model List Model Measurement range General introduction GD2550 2500V/0 ~ 100G Ω ; 5000V/0 ~ 200G Ω ; Analog , Short Circuit Current 1mA GD2533 500V/0 ~ 20G Ω ; 1000V/0 ~ 40G Ω ; 2500V/0 ~ 100G Ω ; Analog, Short Circuit Current 1mA GD2000 2500V/0 ~ 100G Ω ; 5000V
重庆格纳迪机电设备有限公司 [2014-12-07 08:03:30 ]
1.1 Application GDGS automatic tan delta tester is applied to measure the dielectric loss and capacitor value of insulation materials in high voltage power equipment. The non-power frequency voltage source is integrated in the tester to avoid power frequency interference. That ma
重庆格纳迪机电设备有限公司 [2014-12-07 08:01:59 ]
1.1 General introduction The tester can record switch operation waveform in overall process. The longest time is 6.4s It can test various parameters such as transition waveform, transition time, transition resistance and three phase synchronization one time and analyze results au
重庆格纳迪机电设备有限公司 [2014-12-07 08:00:56 ]
1 Functions 1. The voltage ratio measurement for three or singe phase transformer 2. The group vector measurement for three phase transformer. 3. The polarity measurement for single phase transformer or CT/PT 4. Voltage ratio error calculation 5. Current transformer ratio measure
重庆格纳迪机电设备有限公司 [2014-12-07 07:59:30 ]
1.1Application GDZC Series winding resistance tester are applied to measure the DC resistance of inductance circuit such as power transformer coil, current transformer coil and so on. Also the tester could be applied to measure the cable resistance in 4-wire mode. 1.2Functions 1
重庆格纳迪机电设备有限公司 [2014-12-07 07:58:49 ]
1.1Functions 1 Breakdown test of user-defined 2 Proof test 3 Calibration interface for customers 4 Uploading data to PC and making word report automatically. 5 Result print 1.2Technique index 1 Output voltage AC 0~80KV 2 Three vessels test at the same time 3 Rate of voltage rise
重庆格纳迪机电设备有限公司 [2014-12-07 07:58:04 ]
1.1 Functions 1 Breakdown test of user-defined 2 Proof test 3 IEC60156/IS6792/BS5874 test 4 ASTM D1816 standard test 5 ASTM D877 standard test 6 5 minutes standard test 7 Manual test 8 Calibration interface for customers 9 Uploading data to PC and making word report automatically
重庆格纳迪机电设备有限公司 [2014-12-07 07:57:17 ]
1.1 Functions 1 Breakdown test of user-defined 2 Proof test 3 Calibration interface for customers 4 Uploading data to PC and making word report automatically. 5 Result print 1.2Technique index 1 Output voltage AC 0~80KV/AC 0~100KV 2 Rate of voltage rise 2KV/s±10% 3 Measuring pre
重庆格纳迪机电设备有限公司 [2014-12-07 07:56:32 ]
1.1 Functions 1 Breakdown test of user-defined 2 Proof test 3 Calibration interface for customers 4 Result print 1.2Technique index 1 Output voltage AC 0~80KV 2 Rate of voltage rise 2KV/s±10% 3 Measuring precision 3%RDG+0.3%FS 4 Test times setting 1-9 5 Mixing time setting 0~99
重庆格纳迪机电设备有限公司 [2014-12-07 07:55:45 ]
1.1Function Measure the transformer load current, load loss, short-circuit voltage, short circuit (load) losses. 1.2 Test Item RMS phase voltage Average value of three-phase AC voltage Three-phase current RMS Percentage of no-load loss and no-load current Load loss, impedance vol
重庆格纳迪机电设备有限公司 [2014-12-07 07:54:47 ]
Tester Introduction There are four DC currents to select for GDZC-20 which has a large output power , the power of the tester itself is very little. Used four lines, it is quick, stable, high precision for testing the winding resistance . In addition, it has a strong ability fo