Before the curing
Appearance | White paste |
Relative density | 1.60~1.70(g/cm3) |
Surface drying time | â¤15(min) |
After the curing
Tensile strength | â¥1.5(MPa) |
Elongation At Break | â¥150(%) |
Shear strength | â¥2.0(MPa) |
Hardness | 35~45(Shore A) |
Temperature Range | -60~200(â) |
Volume resistivity | 2.2Ã1015 (Ω·cm) |
Dielectric strength | 20 (kV/mm) |
Thermal conductivity | â¥0.8[W/(m·k)] |
Dielectric constant | 3.12(1.2MHz) |
Packaging: 100mL / tube,100tubes / box.
METHOD OF OPERATION
INSTRUCTIONS
1,Clean surface: cleaning adhesion surface and to remove the rust,dust and greasy dirt, etc.
2,After sizing: Unscrew the hose cap (or cutting), squeezing the glue on cleaned surface, so that can be distributed uniformly.
3,Curing: the part of bonded or sealed were cured naturally in the air. The curing is a process from the surface to the internal, the depth of curing is 2 ~ 4mm within 24 hours (at room temperature and 55% relative humidity), if the location of sizing is too deep, especially when it is not easy to contact the air, then the completely curing time will be extended, if the temperature is low, the curing time will be extended either, the fully curing time need at least 7 days if the thickness of sealant is 6mm.
MATTERS NEEDING ATTENTION
NOTE
After operating, the rest of glue must be sealed to store , and tightened the cap immediately. when using it in the next time, if there is a little crust in sealed place, to remove it and it will not affect the normal application. the process of storage , the canal orifices may appear the phenomenon of the curing, to clean it then it can be used again, and the performance of product is not affected.
SPECIFICATION TRANSPORT
STORAGE
1,6 months shelf life if stored below 25 â in cool, dry place, when the product passed its expiration date, it should be confirmed without abnormal phenomenon, then
that can be used.
2,These products don\'t belong to dangerous goods, so they can be transported as normal chemicals. But be careful of leakage.
Advantages Class I Division 1,Group A,B,C,D Zone 1, Zone 2 Class II Division 1,Group E,F,G Zone 21, Zone 22 Class III Type 4X,IP66 Ex d IIC T6 Gb Max.250A Ex tb IIIC T80℃ Db IP66 Built-in Terminal blocks Among all class 1 div 1 junction box types, explosion proof junction ...
Advantages Class I Division 1,Group C,D Zone 1, Zone 2 Class II Division 1,Group E,F,G Zone 21, Zone 22 Class III Type 4X,IP66 Ex d IIB T6 Gb Max.400A Ex tb IIIC T80℃ Db IP66 Built-in Terminal blocks As a class 1 div 1 junction box requesting the most quantity in flammable ...