TGS2602 - for the detection of Air Contaminants
Model number |
TGS2602-B00 |
||
Sensing principle |
MOS type |
||
Standard package |
TO-5 metal can |
||
Target gases |
Air contaminants
(VOCs, ammonia, H 2 S, etc.)
|
||
Typical detection range |
1 ~ 30ppm of EtOH |
||
Standard circuit
conditions
|
Heater voltage |
VH |
5.0±0.2V AC/DC |
Circuit voltage |
VC |
5.0±0.2V DC |
Ps≤15mW |
Load resistance |
RL |
variable |
0.45kΩ min. |
Electrical
characteristics
under standard test
conditions
|
Heater resistance |
RH |
approx 59Ω at room temp.
(typical)
|
Heater current |
IH |
56±5mA |
|
Heater power consumption |
PH |
280mW (typical) |
|
Sensor resistance |
RS |
10kΩ ~ 100kΩ in air |
|
Sensitivity
(change ratio of Rs)
|
0.08~0.5 |
Rs (10ppm of EtOH)/Rs air |
|
Standard test
conditions
|
Test gas conditions |
normal air
at 20±2˚C, 65±5%RH
|
|
Circuit conditions |
Vc = 5.0±0.01V DC
V H = 5.0±0.05V DC
|
||
Conditioning period
before test
|
7 days |