Zirconia O2 Sensors
Flange Mounted Series
The Flange Mount Zirconium Dioxide Oxygen Sensor is designed for easy sealing into a manifold or sampling chamber. Favoured by SST’s aerospace customers and in applications that require high temperature and pressure operation.
FEATURES
• Zirconium dioxide (ZrO2) sensing elements
• Long life, non-depleting technology
• Integral heating element
• High accuracy
• Requires an external interface board to operate
BENEFITS
• No reference gas required
• No need for temperature stabilisation
• Flange mounting
TECHNICAL SPECIFICATIONS
Heater voltage Operating Standby | 4.35VDC ± 0.1VDC (1.85A) 2VDC (0.85A) |
Pump impedance at 700°C | < 6kΩ |
Permissible gas temperature | -100°C to +400°C |
Gas flow rate | 0 - 10 m/s |
Repetitive permissible acceleration | 5g |
Incidental permissible acceleration | 30g |
Oxygen pressure range | 2mbar - 3bar max |
Accuracy | 5mbar max |
Internal operational temp | 700°C |
Response time (10 - 90% step) | < 4s |
Warm up time (prior to sensor operation) | 60s |
Warm up time (from standby) | 20s |
Output stabilisation time | ~ 180s |