1. UV Sensor GUVA-C22SD Features
Gallium Nitride Based Material
Schottky-type Photodiode
Photovoltaic Mode Operation
Good Visible Blindness
High Responsivity & Low Dark Current


2. UV Sensor GUVA-C22SD Applications
UV Index Monitoring
UV-A Lamp Monitoring


3. UV Sensor GUVA-C22SD Outline Diagrams and Dimensions


4. UV Sensor GUVA-C22SD Absolute Maximum Ratings
Storage Temperature: -40~90℃
Operating Temperature: -30~85℃
Reverse Voltage: 5V
Forward Current: 1mA
Optical Source Power Range: 0.1µ~100m W/cm2
Soldering Temperature: 260℃

5. UV Sensor GUVA-C22SD Characteristics (at 25℃)
Dark Current: 1nA Max
Temperature Coefficient: 0.08%/℃
Responsivity: 0.14A/W
Spectral Detection Range: 240~370nm

Active area: 0.076mm2