Product Quick Detail

Minimum Order
1
Place Of Origin
Germany
Brand Name
EPIGAP
Packaging
N/A
Delivery
15 Days

Radiation Type Technology
Case
VUV - visible Schottky contact
GaP
TO-39


Description:

Wide bandwidth and high sensitivity from VUV up to the visible spectrum (150 nm - 550 nm), mounted in hermetically sealed TO-39 package with sapphire window


Application:

Medical engineering (dermatology), output check of UV - lamps and oil or gas burner flame, measurement and control of ecological parameters, radiation control for a solarium, UV water purification facilities


Maximum Ratings

Tamb= 25°C, unless otherwise specified

Parameter Symbol Value Unit
Active area A 4.8 mm2
Temperature coefficient of dark current TC(ID) 7 %/K
Operating temperature range Tamb -40 to +125
Storage temperature range Tstg -40 to +125
Acceptance angle at 50% Sλ φ 120 deg.


Optical and Electrical Characteristics

Tamb = 25°C, unless otherwise specified

Parameter Test conditions Symbol Min Typ Max Unit
Breakdown voltage IR=10µA VR 5

V
Dark current VR=5V ID
15 40 pA
Peak sensitivity wavelength VR=0V λp
440
nm
Responsivity at λP VR=0V 0.1 0.13
A/W
Sensitivity range at 1% of Sλ VR=0V λmin , λmax 150
550 nm
Spectral bandwidth at 50% VR=0V ∆λ0.5
180
nm
Shunt resistance VR=10mV RSH 80 100
GΩ
Noise equivalent power λ=440nm NEP
1.3 x 10-14
W/√Hz
Specific detectivity λ=440nm D*
1.7 x 1013
cm ∙ √Hz ∙ W-1
Junction capacitance VR =0V CJ
1000
pF
  • Country: Hong Kong
  • Business Type:
  • Market:Europe
  • Founded Year:2014
  • Address:
  • Contact:Rita yu
*Your name:
*Your Email:
*To:ISweek company
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters : 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

submiting now We do inquire for you , please wait ...