AMIKON LIMITED
Sales Manager:Nancy
Email:info@amikon.cn
Wechat + 8618020776786
Skype:onlywnn_1
Website: www.amikon.cn
Advantage Brands:
Allen Bradley: Reliance,SLC500/1747/1746,Logix5000/1756,PLC-5/1771/1785
ABB: DSQC series,H&B Freelance,Bailey
Bently Nevada: 3500 System spare parts ,3300 System spare parts
Yokogawa DCS
Honeywell DCS
Ovation: 1C31234G01/1C31227G01/1C31166G01/1C31116G01/1C31189G01 etc DCS System spare
GE: IC693/IC697/IS200/DS200/IS215
Triconex: 3700A/3805E/3604E/3503E/3504E/3008/4119A/8312/3703E/3511/
Schneider 140 PLC series 140CPU67160/140CRP93200/140CPS11420
AMIKON LIMITED to the "professional, integrity, innovation, cooperation, win-win"
business philosophy, and constantly develop new products, to provide quality services, in order
to maximize the pursuit of customer satisfaction, and constantly open up new areas of business for customers.
Replace PROFIBUS connector BP910S of passive line with PROFIBUS connector BP914S. Configure the termination according to the position in the intrinsically safe segment (see Figure 1). Plug the connection again to the Termination Unit (TU921*) and fix the screws. (7) Replace the PROFIBUS isolating repeater: Replace BI912S or BI913S with BI914S Replace BI933S with BI934S. ABB Automation GmbH Doc. Id. 2PAA107378 Rev. - Date. 13.12.2012 6 (13) When replacing the BI912S and BI913S with BI914S, observe the bus termination on the non-intrinsically safe PROFIBUS segment (master side): BI912S -> BI914S with switch S2 =off BI913S -> BI914S with switch S2 =on. The baud rate at the BI914S must be configured using switch S1. The baud rate setting will only be effective after power on. (8) Plug in the passive communication interfaces CI920A* of all S900 stations. (9) Power up the PROFIBUS network components of the passive line (BI914S or BI934S). (10) Connect / insert the PROFIBUS connector of the passive line at master. The passive line has now been completely converted to the physical layer according to the PROFIBUS International Guideline RS485-IS. (11) Check the redundancy availability: The passive communication interface CI920AS V2.1 is pre-initialized by the active communication interfaces CI920S V1.5.9 (does not apply for older communication interface versions CI920* with FW 1.4.x). After a few seconds up to a maximum of 120 seconds, the diagnostic messages in the master must have disappeared. The system must be free of diagnostic messages in terms of redundancy. The LEDs at communication interfaces of an S900 must indicate the following status:
2094-AC05-M01-S
2094-AC05-MP5-S
2094-AC09-M02-S
2094-AL09
2094-AL75S
2094-AM05-S
2094-ANCON-1
2094-BC01-M01-S
2094-BC01-MP5-S
2094-BC02-M02-S
2094-BC04-M03-S
2094-BC07-M05-S
2094-BL02
2094-BL75S
2094-BM01-S
2094-BM02-S
2094-BM03-S
2094-BM05-S
2094-BMP5-S
2094-BNCON-1
2094-BSP2
2094-XL75S-C1
2094-XL75S-C2
2094-PRF
2094-PRS1
2094-PRS2
2094-PRS3
2094-PRS4
2094-PRS5
2094-PRS6
2094-PRS7
2094-PRS8
2094-XNBRKT-1
2094-XNINV-1
2094-XNLIM-2
2094-XNSHT-1