4OXV CiTiceL
Oxygen (O2) Gas Sensor
4OXV CiTiceL Oxygen (O2) Gas Sensor Key Features and Benefits:
• False alarm immunity
• Enhanced response time in extreme applications
• Reliably meets stated life
• Superior environmental performance
4OXV CiTiceL Oxygen (O2) Gas Sensor Technical Specifications
MEASUREMENT | |
Technology | Electrochemical |
Measurement Range | 1-25% vol. O2 |
Maximum Overload | 30% vol. O2 |
Output Signal | 0.10 ± 0.02 mA in Air |
Response Time (T90) | <15 Seconds |
Zero Current (Offset) | <0.6% vol. O2 |
Linearity |
Can be considered linear in many cases. See Operating Principles (OP-02) for further details. |
|
|
ELECTRICAL | |
Recommended Load Resistor | 100 Ω |
|
|
MECHANICAL | |
Casing Material | ABS |
Weight | <16 g |
Orientation Sensitivity | <0.2% vol. O2 equivalent |
|
|
ENVIRONMENTAL | |
Operating Temperature Range | -20°C to +50°C (up to 3 months continuous across RH range) |
Recommended Storage Temp | 0°C to 20°C |
Thermal Transient
(Temp. plunge +22°C to -20°C)
|
<23.5% vol. O2 |
Operating Pressure Range | Atmospheric ± 20% |
Pressure Coefficient | <0.02% signal/mbar |
Pressure Transient
(60 cm H2O step change)
|
<200% signal change |
Relative Humidity Range | (at 0°C to 20°C) |
Continuous | 5 to 95%RH non-condensing |
Short Term | 0 to 99%RH non-condensing |
|
|
LIFETIME | |
Long Term Output Drift |
<2% signal/month Typically <5% over operating life |
Expected Operating Life | Minimum 24 months in air |
Storage Life | 6 months in original packaging |
Warranty Period | 24 months from date of despatch |
4OXV CiTiceL Oxygen (O2) Gas Sensor IMPORTANT NOTES
Obstruction of the vent hole will compromise performance, and must be avoided. Do not remove label.
All tolerances ±0.15 mm unless otherwise stated.DO NOT solder to pins.