IEC 60332-1-1,2,3
EN 50086-1-1994
GBT 18380.11,12-2008
Features:
1, the touch screen intelligent control system; English user interface;
2, the system automatic ignition, automatic timing, automatic datastorage;
3, the test section and the control section is conbined design in onebox for operation;
4, stainless steel test box, the internal cavity size: height 1200mm,width 300mm, depth of 450mm;
6, a pre-mixed burner, an inner diameter of ¢ 12 ± 0.5mm, length is 100mm. 1KW hybrid standard burner,which provides accurate test fire source;
7, the flame burning applied time and hold time can range from 0 to 99 minutes99 seconds range adjustment. Automatic control of the testing process.
8, import needle vavle precisely adjust the flame height, according tostandards, thef blue flame height is 50mm ~ 60mm, total height 170mm ~ 190mm
9, the gas flow rate is controlled by needle valve
10, equipped with a steeless flame height caliper.
Specifiction:
Size | 600(W)×450(D)×1250(H)mm |
Gas pressure | 0.1MPa |
Power | AC220 V +/- 10V 50HZ; |
Weight | 60KG |
Model | GD18380A |
Gas purity | Propane> 95%; compressed air |