NEWARE offers charge/discharge battery testing systems ranging from μA signal cell applications up to 300kw packs.
Application:
1,Coincell,cylindrical,prismatic,&flat cell testing.
2,Basic cycling,electrochemical experiment,and advanced real-world simulations.
3,Battery packs and modules of all sizes.
4,Any battery chemistry including lithium,silicon,sulfur,lead acid,nickel,&more.
Technical Specification:
BTS-5V200A
|
Battery Testing System
|
Model:
|
BTS-
|
5
|
V
|
200
|
A
|
Material Code:
|
CT-4004
|
-5V200A
|
-
|
NA
|
-
|
|
Description
|
Product Specification
|
AC Input
|
AC 220V±10% 50Hz
|
Power
|
7089
|
W
|
Resolution
|
AD: 16bit; DA: 16bit
|
Impedance Input
|
≥1MΩ
|
Voltage
|
Measuring Range
|
25mV~5V
|
Discharge Min Voltage
|
2.5V
|
Accuracy
|
± 0.1% of FS
|
Stability
|
± 0.1% of FS
|
Current
|
Range
|
Charge: 1000mA~200A Discharge: 1000mA~200A
|
Accuracy
|
± 0.1% of FS
|
Stability
|
± 0.1% of FS
|
Power
|
Output Power Per Channel
|
1000W
|
Stability
|
± 0.2% of FS
|
Time
|
Rise Time
|
20ms (10%FS~90%FS)
|
StepTime
|
≤ (365*24) hour/step
|
Time Format 00:00:00:000 (h:min:s:ms)
|
Data Acquisition
|
Intervals
|
Time interval Δt: (100ms~60000s)
|
Voltage interval ΔU: (10mV~5V)
|
Current interval ΔI: (400mA~200A)
|
Frequency
|
10Hz
|
Charge
|
Modes of Operation
|
CCC, CVC, CC & CVC, CPC
|
End Conditions
|
Voltage, Current, Test Time, Capacity
|
Discharge
|
Modes of Operation
|
CCD, CPD, CRD
|
End Conditions
|
Voltage, Current, Test Time, Capacity
|
Pulse
|
Charge
|
CCC
|
Discharge
|
CCD
|
Minimum Pulse Width
|
500ms
|
Automated Switch
|
Automated switch from charge to discharge for each pulse
|
End Condition
|
Voltage, Test Time
|
Cycle
|
Cycles
|
65535
|
Steps
|
254
|
Nested Function
|
Max three levels of loops
|
Protective Function
|
Power-off data protection
|
Off-line Operating
|
User-defined safety (upper and lower) tolerance of current, voltage and delay time
|
Reverse-connecting protection
|
Channel Features
|
Independent pairs of closed loop for constant current source and constant voltage source
|
Channels
|
Independent control
|
Detection and Sampling
|
4-wire Connecting
|
Noise Density
|
<85dB
|
Data Management
|
MYSQL Database
|
Communication Means
|
TCP/IP Protocol
|
Exports Formats
|
EXCEL, TXT, Graph
|
Communication Interface
|
Ethernet Port
|
Number of Channels Per Cabinet
|
4
|
Operating Environment
|
Description
|
Product Specification
|
Operating Temperature
|
0ºC~40ºC
|
Storage Temperature
|
-10ºC~50ºC
|
Operating Humidity
|
≤70% RH
|
Storage Humidity
|
≤80% RH
|
Warraty: 1 year
Delivery: 7days after deposit
Contact information:
Emily Zhang