F2000TSM-TH
Temperature & Humidity Transmitter
CE-Approval
F2000TSM-TH Temperature & Humidity Transmitter Features
• Designed for transmit relative humidity measurement and temperature measurement.
• Provide up to 2x0~10VDC/4~20mA/0~5VDC outputs for humidity and temperature measurements
• Humidity output is automatically corrected over the full range of operating conditions
• Arbitrary point setup of temperature and humidity measurement modification
• Modbus RS485 communication is optional
• Wall mounting with the smart structure
F2000TSM-TH Temperature & Humidity Transmitter Specifications
|
Temperature |
Relative Humidity |
Sensing element |
Digital Temp.&RH combined sensor |
Digital Temp.&RH combined sensor |
Measuring range |
0°C~50°C (32°F~122°F) (default) |
0 -100%RH |
Accuracy |
±0.5°C (20~40°C) |
±4.5%RH (20%-80%RH) |
Stability |
±0.04°C per year |
<0.5%RH per year |
Storage environment |
10~50°C (32°F~122°F) / 20~60%RH |
|
Connection |
Screw terminals |
|
Set measurement zone |
The zero and the end can be set via Modbus |
|
Housing/IP Class |
PC/ABS fireproof material/IP 40 |
|
Output |
0~10VDC(default) or 4~20mA (selectable by jumpers) 0~5VDC (selected at place the order) |
|
Power supply |
24VAC/VDC±10% |
|
Power cost |
≤2W |
|
Resistance permitted |
≤500Ω |
|
Net weight |
180g |
|
Dimensions |
(W)100mm x (H)80mm x (D)28mm |
|
Installation standard |
65mm x 65mm or 2" x 4" wire box |
|
Approval |
CE-Approval |
F2000TSM-TH Temperature & Humidity Transmitter Models Information
Model |
Description |
F2000TSM-TH-M100 |
1Xanalog linear output for temperature measurement. |
F2000TSM-TH-M100-RH |
1Xanalog linear output for RH measurement. |
F2000TSM-TH-M101 |
1Xanalog linear output for temperature measurement. Modbus RS485 interface. |
F2000TSM-TH-M101-RH |
1Xanalog linear output for RH measurement. Modbus RS485 interface can read temperature and RH measurements. |
F2000TSM-TH-M200 |
2Xanalog linear outputs for temperature and RH measurements. |
F2000TSM-TH–M201 |
2Xanalog linear outputs for temperature and RH measurements. Modbus RS485 interface. |
F2000TSM-TH–M001 |
Modbus RS485 interface for temperature & RH measurements. |
Postfix 1: |
type of output signal |
-V 0~10VDC (default) -A 4~20mA -V5 0~5VDC (not be changed ) |
|
|
|
Postfix 2: |
temperature scaling |
T05: 0°C~50°C (32°F~122°F) default (without the postfix indicates the default) T06: 0°C~60°C (32°F~140°F) T26: -20°C ~60°C (-4°F~140°F) |
For example:
F2000TSM-TH-M100-V5-T06 indicates the transmitter with 1X 0~5VDC output, and the temperature scaling is 0~60°C.
F2000TSM-TH-M200-A indicates the transmitter with 1X 4~20mA output, and the temperature scaling is the default (0~50°C).
The controller for temperature and humidity is suitable for adjustment and control of temperature and humidity in equipments of high voltage switchgear, terminal box, ring network panel, box transformer substation etc. It can effectively protect relevant equipment from faults ...
Digital Temperature and Humidity Controller for Sale The WHD series temperature and humidity controller uses sensors to detect the temperature and humidity values in the cabinet and adjusts the temperature and humidity values by controlling the external fan and heater, which ...