Specifications | ||
01 | Pressure Range | 0.35bar, 1bar, 2.5bar, 6bar, 10bar, 16bar, 25bar, 60bar, 100bar, 250bar, 400bar, 600bar |
02 | Overload Capacity | 1.5 times scale |
03 | Accuracy | ±0.25%F.S, ±0.5%F.S |
04 | Zero Temperature Coefficient | ±0.015%F.S/ºC(Typical) |
05 | Sensitivity Temperature Coefficient | ±0.015%F.S/ºC(Typical) |
06 | Power Supply | 24VDC |
07 | Output | 4~20mA |
08 | Operating Temperature | -40ºC~+120ºC |
09 | Compensated Temperature | 0~+70ºC(Typical), -40ºC~+100ºC(optional) |
10 | Long Term Stability | ±0.1%F.S/ year |
11 | Anti-exploding Performance | Intrinsic safety against exploding ExiaII BT6 (HB9500) |
12 | Pressure Connection |
M20×1.5, G1/4 male, Customized (Customer should provide connector drawing) |
13 | Electrical Connection |
Hirschman Connector, Hummel water-proof connector, Cable Connection |
Notes |
1.Accuracy includes hysteretic, repeatability and nonlinearity (the Least Square Method) 2.Without other notices, all results are attained with the reference temperature 25ºC |
HB2126 Pressure Transmitter Order Information | ||
|
Code | Measuring Type |
A | Absolute Pressure | |
G | Gauge Pressure | |
|
Code | Pressure Range |
0003 | 0~0.35bar | |
0010 | 0~1bar | |
0025 | 0~2.5bar | |
0060 | 0~6bar | |
0100 | 0~10bar | |
0160 | 0~16bar | |
0250 | 0~25bar | |
0600 | 0~60bar | |
1000 | 0~100bar | |
2500 | 0~250bar | |
4000 | 0~400bar | |
6000 | 0~600bar | |
|
Code | Accuracy |
A1 | ±0.25%F.S | |
A2 | ±0.5%F.S | |
|
Code | Compensated Temperature |
T1 | 0~70ºC | |
T2 | -40~100ºC | |
T0 | Customer requirement | |
|
Code | Electrical Connector |
EC1 | Hirschman Connector | |
EC2 | Cable Directly | |
EC0 | Customer requirement | |
|
Code | Pressure Connector |
PC1 | M20×1.5 | |
PC2 | G1/4 male | |
PC0 | Customer requirement |
The cavity has high accuracy and a wide range; the cavityless is easy to clean and is suitable for liquid pressure measurement with impurities. Pressure sensors are usually used in chemical, metallurgical, aerospace, and other industries. TBP-1 Diffused Silicon Pressure Sensor ...
LEFOO LFT2800 pressure transmitter is widely used in the measurement of fluid medium pressure in test systems such as fire protection, water treatment, water supply systems, air compressors, pneumatic devices, and factory automation. It has excellent anti-corrosion and ...
LEFOO LFT2800 pressure transmitter is widely used in the measurement of fluid medium pressure in test systems such as fire protection, water treatment, water supply systems, air compressors, pneumatic devices, and factory automation. It has excellent anti-corrosion and ...