1. Introduction
Ø SPF223 sampling probe used in the systems for gas sampling, filtration and heating function, can effectively prevent the condensation of gas samples collected, unique structural design allows for a sampling system is more reliable, more small gas loss rate to ensure system stability and true
2.Features
Ø The device and the part of the sample contact are all made of 316L stainless steel material processing, high temperature resistance, strong corrosion resistance. With rain cover can do outdoor work environment.
Ø Adopting the isothermal heating body, in the design of compact structure, stable heating temperature.
Filter element is made of sintering titanium alloy which has big filter area, high accuracy, small air lock, and can be replaced from the device pulled out completely, simple operation, without tools, greatly shorten the maintenance time, and reduce the labor intensity.
Ø Optionally providing a reusable purging / calibration port.
Ø Operation is simple, with low temperature alarm.
Ø The filter replacement without tools.
Ø The switch is convenient, with locked cover.
Ø High efficiency filter cleaning system.
3.Specifications
Ø Maximum sampling temperature: 300℃
Ø Maximum working pressure: 6BAR
Ø Sampling chamber heating temperature: 140℃ (factory set, adjustable temperature)
Ø Power supply: 220VAC 50/60Hz max 500W
Ø Environment temperature: -20~80℃
Ø Maximum dust load: 100g/m3
Ø Filter accuracy: 5μm (other precision optional, 1-10μm)
Ø Filter size: 150*35mm
Ø Purging gas interface: OD8/6mm connector
Ø Sample gas outlet: OD8/6mm connector
Ø The sampling pipe containing: 25 * 1200mm(length is optional)
Ø Flange size: DN65PN6
Ø The installation of accessories: installation flange & fixing bolts & flange sealed pad
4. Internal pictures