KR-605 Fully Automatic Karl Fischer Moisture Titrator

FOB Price
USD $2,100.00 / Piece
Place Of Origin
China
Minimum Order
1
Packaging
wooden box
Delivery
7 Days

pplication:

This KR-605 water content tester adopts the global recognized classical moisture testing method - Karl Fischer Coulometric Method which is the most accuratemethod with low cost. With the universal standard and analyzing method, it can quickly analyze the moisture content in liquid, solid and gas and directly display testing results, with testing range from 0.0001%(1ppm) to 100%. Therefore, this testing method has been widely used in institutions and enterprises of petroleum, chemical industry, power, pharmaceuticals, pesticide, railways, research, etc.

The whole testing process is automatically controlled by this tester itself. Its auto-stirring and analyzing would be finished within 60seconds, and results would be displayed directly. Totally closed titration system avoids damage to operator from reagent. Equipped with 500ml Karl Fischer Reagent, which could test about 1000 times sample continuously, completely avoiding big deviations of other moisture testing method and thus improving quality index of products.

Application Area

Liquid Chemical Industry:alcohols, ethers, esters, alkenes, benzenes, amines, organic solvents, phenols and other organic products applicable to Karl Fischer Method for determination

Petroleum and Power Industry:Insulation Oil, Transformer Oil, Turbine Oil, etc.

Pharmaceutical Industry:medicine materials

Pesticide Field:emulsifier

Other Industry:electrolyte of lithium battery

Solid Various mineral salt, citric acid, explosives, paraffin and other solids with good solubility
Gas Natural gas, liquefied gas, Freon, butadiene, chloromethane, etc.

Features:

1. Powerful Itanium and double CPU; direct A/D conversion of testing electrode data.

2. 7 inch color touch screen LCD display in English. Function of reagent failure prompt, extending the service time of it.

3. Completely closed titration system avoids direct touch between people and the reagent as well as the influence of environmental humidity.

4. The outer shell is made of high-quality cold-rolled steel plate with electrostatic sprayed surface, anti-corrosion and easy to clean.

5. Auto-control and compensation of electrical current via MCU contributes to quick balance of reagent.

6. Auto-control electrolysis current within 430mA ensures high sensitivity and fast analyzing speed.

7. Preinstalled with cubature (including 3 pieces of formula), statistical calculation (including average calculation, standard deviation calculation and rate of change calculation) and elementary arithmetic, with the advantages of auto-analysis and calculation.

8. Automatically tests the sample, analyzes and displays results, and calculates the average value of several times of test.

9. Infinite capacity of results storage is convenient to consult previous testing data whenever necessary.

10. Automatically calculates and prints the following content: ug / ppm / percentage / mg/L / sample number / experimenter / testing date, etc.

11. Network management available by connection with laptop or computer communications through USB or RS232 interface.

12. Multilanguage display available. The program of tester can be upgraded accordingly if related national standard is revised.

Technical Parameters

Method of Display 7 inch color touch LCD with English display
Method of Testing MPU controlled electrolysis(Karl Fischer Coulometric Method)
Rate of Electrolysis 3.0mgH2O/min
Electrolysis Current Auto-control within 430mA
Testing Range 0.01ugH2O-200mgH2O
Water Content Range 0.0001%(1ppm)—100%
Sensitivity 0.01ugH2O
Accuracy Water Content: 2ugH2O-100ugH2O; Deviations≤±1ug,

Water Content: 100ugH2O-1000ugH2O; Deviations≤±2.9ug,

Water Content:>1000ugH2O; Deviations≤±0.2%(excluding deviations of sample injection)

Drift Compensation Auto-control via MPU
Stirring Speed Adjustable and steerable
End-point Indication LCD display /output via printing / voice warning / end-point indication light
Data Input Input via touch screen
Sample Number Numbered by users
Storage Infinite storage capacity
Printer Thermal printer, high-speed, low-consumption, with 44 millimeter-wide paper
Printing Content ug / ppm / mg/L / sample number /experimenter / date
Calendar/Clock automatic display and print analyzing time and date
Self-checking Breakdown self-checking
Special Function Work independently or connected with laptop or other computers
Power Consumption <40W
Dimension 390×270×190mm
Working Environment Temperature:5℃-40℃,Humidity:<85%
Power Supply AC220V±10% 50HZ±2.5HZ
Weight About 7kg
  • Country: China (Mainland)
  • Business Type:
  • Market:
  • Founded Year:
  • Address:
  • Contact:Julie Wang
*Your name:
*Your Email:
*To:Chongqing Kolery Trading Co., Ltd
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters : 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

submiting now We do inquire for you , please wait ...

DSHD-2122B Automatic Karl Fischer Titrator
DSHD-2122B Automatic Karl Fischer Titrator

A:Brief description:     DSHD-2122B Automatic Karl Fischer Titrator is designedaccordingthe National Standard of People\'s Republic of China GB7600 Test Method for Water Content of Transformer Oil in Service (Coulometric Method), and the Industry Standard of People\'s ...

Dshing Instrument Co.,Ltd

GD-2122B Automatic Karl Fischer Titrator
GD-2122B Automatic Karl Fischer Titrator

Summary The instrument is designed and made as per national standard of China GB/T 7600 Standard Test Method for Water Content of Transformer Oil in Service (Coulometric Method), industrial standard of China SH/T0246 Standard Test Method for Water Content of Light Oils ...

重庆格纳迪机电设备有限公司