LIGHTEARTH UVC tube manufacturer provides 20W/30W/40W/75W 220V Quartz Glass ultraviolet germicidal tube with Bracket for customers.
Ultraviolet rays can cause burns to the eyes and skin.When the ultraviolet germicidal lamp starts, people and animals plant must leave the scene to avoid direct view UV rays! After using the end of
ultraviolet germicidal lamp, it is recommended to ventilate for 30-45 minutes!
Specification of Ultraviolet Germicidal Lamp
Type Input Power Shell Material POWER Base Life
LP-GZ202 AC220V 50/60Hz Cold plate spray 20W G13 9000H
LP-GZ302 AC220V 50/60Hz Cold plate spray 30W G13 9000H
LP-GZ402 AC220V 50/60Hz Cold plate spray 40W G13 9000H
LP-GZ752 AC220V 50/60Hz Cold plate spray 75W G13 9000H
LP-GZ303 AC220V 50/60Hz Aluminum alloy 30W G13 9000H
LP-GZ403 AC220V 50/60Hz Aluminum alloy 40W G13 9000H
LP-GZ753 AC220V 50/60Hz Aluminum alloy 75W G13 9000H
How to choose the UV sterilization lamp?
Service life
Generally the average life of UV sterilization lamp is 8000h, and high-performance UV sterilization lamp can reach more than 10,000 hours.
In daily use, every once in a while to wipe the UV sterilization lamp, every 1-2 years to replace it, to ensure that the radiation intensity of the UV sterilization lamp at work.
UV sterilization lamp material
Currently on the market UV sterilization lamp material has a quartz tube, high boron tube two. Taking into account the high boron tube UVC lamp irradiance may not meet the standard, where it is
recommended that you give priority to the purchase of quartz ultraviolet germicidal tube to ensure radiation intensity.
UV sterilization lamps in the work of physical disinfection, no secondary pollution, low energy consumption, kill viruses and bacteria with a broad spectrum. Meanwhile, UV sterilization lamp does
not produce other chemical pollutants. As such advantages, you can save the UV disinfection system cost.
Is Ultraviolet germicidal irradiation safe?
The limitation of UV disinfection is that it can only be used for disinfection of indoor air in unoccupied condition, the doors and windows need to be closed during disinfection, and the room
should be ventilated after irradiation, at this time, the disinfection state of indoor air will be gradually destroyed, and will return to the original state after about 20 minutes, therefore, UV
disinfection is more suitable for disinfection of indoor air before aseptic operation and final disinfection of infectious diseases: such as the consultation room of receiving infectious diseases,
infectious disease wards, and final disinfection of multi-drug-resistant bacteria patients after discharge, in order to completely kill indoor pathogenic microorganisms and prevent the spread and
dissemination of germs.
If you need any kinds of uvc ozone sterilization lamp, please contact us, as a professional germicidal lamps supplier, LIGHTEARTH is willing to offer you high quality products.