Acrel medical isolated power supply systems are mainly used in operating rooms, ICU/CCU intensive care units, premature infant care units, delivery rooms, hemodialysis centres, and emergency rooms.
The hospital isolated power systems provide safe, reliable and continuous power distribution for important equipment in these places. They can realize the conditions of insulation, load and
isolation transformer temperature of IT system. Real-time monitoring with functions such as system insulation fault circuit location and centralized monitoring of multiple systems.
Medical Isolated Power Supply System For Sale
Hospital isolated power systems provide safety, continuous and reliable power supply, real-time detection of the insulation state to the ground to ensure the life safety of patients. Insulation
fault location, convenient maintenance.
Hospital Isolated Power Systems Data Sheet
Technical Parameters of AITR Series of Medical Isolation Transformer
Type AITR10000 AITR8000 AITR6300 AITR5000 AITR3150
Insulation class H H H H H
Protection class IP00 IP00 IP00 IP00 IP00
Power/voltage/ current
Rated power 10000VA 8000VA 6300VA 5000VA 3150VA
Rated frequency 50/60Hz 50/60Hz 50/60Hz 50/60Hz 50/60Hz
Rated input voltage AC230V AC230V AC230V AC230V AC230V
Rated input current 45.3A 36A 28.5A 22.5 14.2A
Rated output voltage AC230V/115V AC230V/115V AC230V/115V AC230V/115V AC230V/115V
Rated output current 43.5A 34.7A 27.4A 21.7 13.7A
Inrush current <12In <12In <12In <12In <12In
Leakage current <200μA <200μA <200μA <200μA <200μA
No load input current 1.359A 1.08A 0.855A 0.675A 0.426A
No load output voltage 235V±3% 235V±3% 235V±3% 235V±3% 235V±3%
Short circuit voltage <6.9V <6.9V <6.9V <6.9V <7.5V
General parameters
Fuse wire 80A 63A 50A 35A 25A
Primary winding resistance <55mΩ <64mΩ <80mΩ <131 mΩ <245mΩ
Secondary winding resistance <45mΩ <64mΩ <80mΩ <116 mΩ <228mΩ
Iron loss <150W <105W <107W <77W <55W
Copper loss <230W <200W <170W <125W <120W
Efficiency >96% >96% >96% >96% >95%
Maximum ambient temperature <40℃ <40℃ <40℃ <40℃ <40℃
No-load temperature rise <36℃ <33℃ <31℃ <26℃ <22℃
Full load temperature rise <65℃ <76℃ <67℃ <62℃ <55℃
Noise grade <40dB <40dB <40dB <40dB <40dB
Isolated Power System Purpose
Medical isolated power panels provide safe, reliable and continuous power distribution for the important equipment at these locations:
Used for the transformation of TN system into IT system (ungrounded system)
Functions of real-time monitoring and fault alarming of the ground insulation resistance, transformer load current and transformer winding temperature of the monitored IT system
When the monitored IT system has an insulation fault, the medical isolation panel, hospital isolation panel can initiate and generate the fault location signal to the system, and realize fault
locating function with the help of the fault locator
Acrel isolation panels in operating rooms can remotely monitor the real-time operating conditions of up to 16 pieces of systems, and the main interface intuitively displays whether the access
system communication is intact
Medica/Hospital Isolated Power Systems FAQs
What is hospital isolated power system?
It is an isolation panel operating room that conducts insulation monitoring and fault determination of the power distribution system, to further provide safe, reliable and continuous power
distribution.
What are functions of medical isolated power panels?
What's the consists of medical isolated power supply system?
What are the applications of hospital isolated power systems?