Acrel ADL series products adopt DIN35mm guide rail installation structure, compact size, can measure electric energy and other electrical parameters, clock, rate time and other parameters can be
set, high precision, good reliability, performance indicators in line with CE, UL certification of the technical requirements of the energy meter, and has the power pulse output function; RS485
communication interface can be used to realize data exchange with the host computer.
ADL Series Din Rail Energy Meter For Sale
Acrel din rail mounted energy meter is suitable for government agencies and large public buildings to measure electric energy by item, and can also be used for enterprises and institutions for
electric energy management.
ADL3000-E Three Phase Multifunction Energy Meter
ADL400 Three Phase Din Rail Energy Meter
ADL200 Single Phase Din Rail Energy Meter
ADL100-ET Single Phase Din Rail Energy Meter with CT
ADL10-E Single Phase Din Rail Energy Meter
ADL Series Din Rail Energy Meter Datasheet
Type ADL10-E ADL100-ET ADL200
Voltage Reference voltage AC 220V AC 220V AC 220V
Reference frequency 45-65 Hz 50Hz 50Hz
Consumption <10VA( Single phase) <10VA <10VA
Current Maximum current 60A 60A,100A 80A
Starting current 0.004 Ib 4‰Ib 0.01A
Consumption <4VA(Maximum current) <4VA <1VA
Measurement performance Accuracy Class 1 kWh Class 1 kWh Class 0.5
Standards compliant IEC 62053-21:2003 IEC 62053-21:2003 IEC 62053-21:2003
Pluse Pluse width 80+20 ms 80±20ms 80±20ms
Pluse constant 3200 imp/kWH 1600imp/kWh 1000imp/kWh,10000imp/kWh
Communication Interface RS485 RS485(A+、B-) RS485
Protocol Modbus-RTU Modbus-RTU Modbus-RTU
Outling L*W*H(mm) 18*88*70 88*36*70 90*36*65
Temperature range Work -25℃-55℃ -25℃~55℃ -25℃-55℃
Storage -40℃-70℃ -40℃~70℃ -40℃-70℃
Humidity ≤95%(No condensation) ≦95% (No condensation) ≦95% (No condensation) ≦95% (No condensation)
Altitude <2000m <2000m <2000m <2000m
Type ADL400 ADL3000
Voltage Reference voltage 3*57.7/100V, 3*220/380V, 3*100V, 3*380V 3*57.7/100V,3*220/380V,3*100V,3*380V
Reference frequency 45-65 Hz 50Hz
Consumption <10VA( Single phase) <10VA(Single phase)
Current Maximum current 6A,80A 6A,80A
Starting current Direct connect:0.004 Ib;Connect via:0.001 In Direct connect:0.004lb;Connect via:0.001ln
Consumption <4VA(Single phase rated current) <1VA(Single phase rated current)
Measurement performance Accuracy Class 0.5S Class 0.5
Standards compliant IEC 62053-21:2003 IEC 62053-22:2003
Pluse Pluse width 80+20 ms 80+20 ms
Pluse constant 400imp/kWH,6400imp/kWH 400imp/kWH,6400imp/kWH
Communication Interface RS485 RS485
Protocol Modbus-RTU Modbus-RTU
Outling L*W*H(mm) 72*88*70 126.5*88*69.5
Temperature range Work -25℃-55℃ -25℃~55℃
Storage -40℃-70℃ -40℃~70℃
Humidity ≤95%(No condensation) ≦95% (No condensation) ≦95% (No condensation)
Altitude <2000m <2000m <2000m
Working principle Of Din Rail Energy Meter
ADL Series 3 phase kwh meter din rail use electronic circuits/chips to measure electrical energy; With partial pressure resistance or voltage signal into voltage transformer can be used for
electronic measurement of small signal and current signal in the shunt or current transformer can be used for electronic measurement of small signal, using special power measurement chip will
transform a good voltage and current signals are analog or digital multiplication, and electricity were accumulated, and then output frequency is proportional to the power of the pulse signal,
Digital display after microcomputer processing.
ADL Series Din Rail Wireless Energy Meter FAQs
How To Calculate Maximum Demand In Energy Meter?
We will write the maximum demand function into the program of the energy meter, just need to click the button to turn the page to view the maximum demand.
How Energy Meter Calculate Power Factor?
Our energy meter has the function of measuring the power factor, and the corresponding power factor can be directly viewed on the display interface.
How Energy Meter Works?
When the energy meter is connected to the circuit under test, it will sample the voltage, current and other signals on the line to the chip, and then send to MCU through pulse, and then complete
the calculation and display of various power parameters.
Now the price of 3 phase power meter modbus is reasonable, anything you need, please contact us.