CSD-N150 is a non-insulated system for aluminum sliding patio doors with a modern flat design. The system meets a wide range of needs using common profiles for the construction of simple sliding
typologies. Ideal solution for large spans and warmer climates.
Overview of CSD-N150 Sliding Door
System Sliding Door(Non-Thermal Break)
Model No. CSD-N150
Material Aluminum Alloy/Glass
Hardware Chinese top brand(Kin Long)/Germany brand
Glass Type Tempered/Float/Laminated/DGU/Ceramic Fritted/LowE/Tinted/Reflective/Heat Soak
Cooperated Glass Brand Vitro(Formerly PPG)/Pilkington/Xinyi(SYG)/Yaopi(SYP)/Fuyao/Southglass(SG)/Kibing/CNG/TaiwanGlass
Surface Treatment Powder Coating/PVDF/Anodized/Electrophoresis/Wooden Grain
Profile Brand 6063-T5/6063-T6
Thermal Profile Non-Thermal Break
Standards In Compliance With ASTM/AS/NZS/AAMA/NFRC/EN/BSI/ISO
Application Residential Apartment, Villa/Commercial Hotel, Mall, Office, Public Organization
System Customization Available
Data of CSD-N150 Sliding Door
Testing Data of CSD-N150 Sliding Door
Test Pressure Results
Preloading(Clause 8.2.2 of AS/NZS4284:2008) +1.81kpa No separation, plastic deformations or deleterious was observed.
-2.68kpa
Preliminary Water Penetration Test under Static Pressure (Clause 8.2.3 of AS/NZS 4284:2008) +543kPa There were no leaks.
Preliminary Water Penetration Test under Cyclic Pressure (Clause 8.2.3 of AS/NZS 4284:2008) 272-300-272 (Pa) There were no leaks.
362-724-362 (Pa)
543-1086-543 (Pa)
Structural Test at Serviceability Limit State Wind Pressure (Wsls)(Clause 8.3 of AS/NZS 4284:2008) +1.81kpa No glass breakage, no collapse and permanent deformation were observed. Deflections of
mullions and transoms as well as glass panel were within the allowable deflection limits.
-2.68kpa
Air Infiltration Test (Clause 8.4 of AS/NZS 4284:2008) +/-150Pa The rate of air leakage of the specimen was within the allowable values.
Operating force test (AS 2047-2014, Clause 2.3.2.4) -- The operating force of the specimen was within allowable value.
Water Penetration Test under Static Water Penetration Test under Static 4284:2008) +543Pa There were no leaks.
Water Penetration Test under Cyclic Pressure (Clause 8.6 of AS/NZS 4284:2008) 272-300-272 (Pa) There were no leaks.
362-724-362 (Pa)
543-1086-543 (Pa)
Structural Proof Test at Ultimate Limit State Wind Pressure (Wuls) (Clause 8.8 of AS/NZS 4284:2008) +2.79kpa No collapse of the test specimen was observed under the specified pressure.
-4.15kpa
Thermal Data of CSD-N150 Sliding Door
NFRC procedures NFRC100SB, NFRC200-2010 and NFRC500-2010
Software tools THERM 7.4.3.0 and WINDOW 7.4.6.0
Configuration 6mm LB13-45HS+12A+6mm Clear HST
Panel Dimension 1900mm Wide x 2750mm High
Frame Painted Aluminum
Panel U-value 3.771W/m2k
Visible Light Transmission 0.28
Condensation Resistant 19.1
Frame Data of CSD-N150 Sliding Door
Parts Location Frame Area/m2 Edge Area/m2 U-Value(Frame) U-Value(Edge)
W/m2k W/m2k
Left Header 0.121 0.049 7.9102 2.2952
Left Jamb 0.326 0.154 11.1172 2.0309
Right Header 0.118 0.049 9.5335 2.1194
Mullion 0.117 0.3 22.6254 1.9365
Right Jamb 0.341 0.154 8.7912 2.1402
Left Sill 0.11 0.049 7.784 2.2897
Right Sill 0.113 0.049 11.4681 2.1552
Glass Data of CSD-N150 Sliding Door
Glass Data: 6mm LB13-45HS+12A+6mm Clear HST
Visible Light SHGC SC NFRC U-value STC
W/m3k(Argon)
T% R-out% R-in% Winter Summer
40 20 13 0.26 1.43 1.36 36
Benefits of CSD-N150 Sliding Door
High security level
Modern design
Slim lines for sliding typologies with maximum visibility
Great ease of use and high functionality
Increased static loads and functionality in case of severe weather conditions
Exceptional quality with certified performances
Exceptional sound insulation
Ideal for wide spans
Recommended CAS Facade Products
Our products are designed to snap together perfectly, organically or with the help of couplers. This ensures a streamline design throughout your project. Below is a list of compatible products.
As one of aluminum sliding glass door manufacturers, we will do our best to meet all the needs of customers.
If you want to know more details of residential building facade design, please visit our website.