Thrombite™ Clot Retriever Device

Minimum Order
1
Packaging
N/A
Delivery
15 Days
OVERVIEW
Thrombite™ Clot Retriever Device
HELICAL OPEN-SIDE STRUCTURE
HIGHER ACUTE RECANALIZATION RATE
The Thrombite™ endovascular clot retrieval , featuring S-shaped helical open-side structure, is designed for more efficient clot removal and optimum revascularization in a wide range of vessels.

PRODUCT FEATURES
HELICAL OPEN-SIDE STRUCTURE

enables Thrombite™ clot retriever to efficiently entwine and clamp the clot

assures clot retention for confident removal and revascularization

OVERLAPPED STENT AT THE HELICAL OPEN-SIDE STRUCTURE

increases contact surface with thrombus and maximizes clot integration

EXCELLENT FLEXIBILITY AND VESSEL WALL APPOSITION

optimizes clot retention during smooth navigation through the tortuous anatomies

Radiopaque markers on the distal end of the device increase device visibility
3 markers for the sizes with 3.0 and 4.0mm diameter

4 markers for the sizes with 5.0 and 6.0mm diameter

Advanced stent surface treatment process
RADIAL FORCE
High radial force is designed for clot integration at the initial stage of stent expansion

Low radial force at nominal stent diameter ensures atraumatic retrieval

RADIAL FORCE
How a Stent Retriever Procedure Is Performed
Stent retriever procedure is generally performed in patients with the indications of acute cerebral infarction within six hours. After femoral artery puncture, the catheter is inserted after sheath puncture, and DSA is performed along the catheter to the brain to find the position of blocked vascular. Make the stent retriever reached the position and passing through the clot. Then release to capture the clot. After that, the stent retrieval device will be extracted along with the clot and finally leave your body.

ORDERING INFORMATION OF CLOT RETRIEVAL DEVICE

STENT RETRIEVAL DEVICE STRUCTURE
Thrombite™ Product code Diameter D(mm) Recommended Vessel Diameter(mm) Recommende Microcatheter ID (inch) Working Length A(mm) Stent Length B(mm) System Length(mm)
Min. Max.
3MM CRD-3-15 3 1.5 3 0.21 15 27 1900
CRD-3-20 3 1.5 3 0.21 20 32 1900
CRD-3-25 3 1.5 3 0.21 25 37 1900
CRD-3-30 3 1.5 3 0.21 30 42 1900
4MM CRD-4-15 4 2 4 0.21 15 27 1900
CRD-4-20 4 2 4 0.21 20 32 1900
CRD-4-25 4 2 4 0.21 25 37 1900
CRD-4-30 4 2 4 0.21 30 42 1900
5MM CRD-5-15 5 2.5 5 0.027 15 27 1900
CRD-5-20 5 2.5 5 0.027 20 32 1900
CRD-5-25 5 2.5 5 0.027 25 37 1900
CRD-5-30 5 2.5 5 0.027 30 42 1900
6MM CRD-6-15 6 3 5.5 0.027 15 27 1900
CRD-6-20 6 3 5.5 0.027 20 32 1900
CRD-6-25 6 3 5.5 0.027 25 37 1900
CRD-6-30 6 3 5.5 0.027 30 42 1900

INDICATIONS
Thrombite™ Clot Retriever Device
The Thrombite™ clot retrieval device is intended to restore blood flow by removing thrombus from a large intracranial vessel in patients experiencing ischemic stroke symptom onset.

Zylox Tonbridge Medical highlights the corporate social responsibility and mission, and boosts the innovation and technological development by taking active part in the combination of scientific innovation with medical engineering.
  • Country: China (Mainland)
  • Business Type:
  • Market:
  • Founded Year:2012
  • Address:
  • Contact:Zylox com
*Your name:
*Your Email:
*To:ZYLOX-TONBRIDGE MEDICAL TECHNOLOGY CO., LTD.
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters : 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

submiting now We do inquire for you , please wait ...

Thrombite™ Clot Retriever Device
Thrombite™ Clot Retriever Device

More efficient choice of recanalization HELICAL OPEN-SIDE STRUCTURE HIGHER ACUTE RECANALIZATION RATE The Thrombite™ Clot Retriever Device, featuring S-shaped helical open-side structure, is designed for more efficient clot removal and optimum revascularization in a wide range ...

ZYLOX-TONBRIDGE MEDICAL TECHNOLOGY CO., LTD.