UTG300,300D,300DL Ultrasonic Thickness Gauge,Ultrasonic Thickness Gauge,Thickness Gauge
Color 320x240 Pixels Display
A-Scan Snapshot
Echo-Echo Mode(Thru Paint & Coatings)
Stores 100,000 Readings
Gain: Low, Medium or High for varying test conditions
Type | UTG300 | UTG300D | UTG300DL |
Color Display | √ | √ | √ |
A-Scan Snapshot | √ | √ | √ |
Gain: Low, Medium, High | √ | √ | √ |
Min/Max Capture | √ | √ | √ |
DIFF/RR% | √ | √ | √ |
Thru-paint | X | √ | √ |
Data Logger | X | X | √ |
Data View Software | X | X | √ |
Instrument Specifications | |||
Display Type | 2.4" color OLED, 320X240 pixels, contrast 10,000:1 | ||
Operating Principle | Pulse echo with dual element transducers | ||
Measuring Range | 0.60mmto 508mm(0.025" to 20.00"), depending on material, probe and surface condition | ||
MeasuringResolution | Selectable 0.01mm, 0.1mm(selectable 0.001", 0.01") | ||
Units | Inch or Millimeter | ||
Gain | Low, Medium or High for varying test conditions | ||
Display Mode | Normal, Minimum / Maximum capture, DIFF/RR% | ||
V-Path Correction | Automatic | ||
Update Rate | Selectable 4Hz, 8Hz, 16Hz | ||
MaterialVelocity Range | 500 to 9999m/s (0.0197 to 0.3937in/us) | ||
Languages | Selectable Chinese, English, Japanese | ||
Alarm Settings | Minimum and Maximum alarms. Range of 0.25 mm to 508 mm (0.010" to 20.00"). Dynamic waveform color change on alarm | ||
Power Requirements | 2 AA size batteries | ||
Operating Time | Approximately 40 hours | ||
Instrument Shut-off | Selectable ALWAYS ON or AUTO OFFafter 5, 10, 20 minutes of inactivity | ||
Operating Temperature | -10°Cto +50°C (+10°F to +120°F) | ||
Size | 153mmX 76mm X 37mm(H X W X D) | ||
Weight | 280gincluding batteries | ||
Data Logger Option Features | |||
Capacity | 400 files, 100,000 readings | ||
File Structure | Grid file | ||
Rows X Columns | 21 X 12 | ||
CommunicationPort | USB 2.0 (Full Speed ) port | ||
Software | Data View PC software |