Brief
It’s a rapid test strip which is used for testing tissue samples and water. The detection limit is 5 ppb.
<!--[if !supportLists]-->1. <!--[endif]-->Introduction
Malachite green is a toxic chemical primarily used as a dye. When diluted, it can be used as a topical antiseptic or to treat parasites, fungal infections, and bacterial infections in fish and fish eggs. It is also used as a bacteriological stain. Malachite green and its major metabolite, leuco-malachite green have been reported to have mutagenic and carcinogenic effects. The use of this substance has been banned in many countries as a suspected carcinogen. Lab tests revealed that rats fed malachite green at the concentration of 100 ppb for longer than 2 years showed signs of tumors.
<!--[if !supportLists]-->2. <!--[endif]-->Principle
When a sample is added to the Malachite green Test Strip, the sample begins to mix with the colloidal goldlabeled antibody and simultaneously moves along the strip membrane by capillary action. In the sample region of the test strip, if Malachite green is present, the second specific antibody captures the colloidal gold-labeled antibody and bound Malachite green, forming a colored line or band in the “T” window of the test strip. As an internal control, a second band visualized in the control (“C”) window of the test strip is an indication that the test strip functioned properly. Two bands or colored lines (in the “T” and “C” windows) are required for a positive result determination.
2. Contents
1 Test cassette
2 Manual
3. Sample preparation
1 Sample handling: take the edible part of the aquatic product after using minced meat grinder accurately weighed 10.0g in 50mL centrifuge tube, adding extractant A 5mL, extraction agent B 7mL, shake for 5 minutes then mixing centrifuge 4000 turn centrifugation for 5 minutes (on-site available filter paper), take the supernatant 4mL in 50mL centrifuge tube, add 3 drops of buffer, then diluted to 25mL.
2 Through column chromatography (chromatography on the sample in 1.5mL activator to be added before the activation of chromatography, column chromatography plus 4mL distilled water): the supernatant fractionated column chromatography, using extraction unit Under pressure from the mouth, to speed up the flow rate, 25mL sample through the column suggested time for 5-8min. Flow of sample liquid to be completely dry, add 4mL distilled water columns.
3 Derivative: the 1mL diluted derivatization reagent added to the chromatography column in the flow of dry completely, then add 2mL distilled water and squeezed, then 1mL elution eluate collected [Note: To control the flow as slowly as possible] (first 11 with the drip drip drip bottle elution, wash the ears with ball pressure, flow to be completely dry, and then drops 11 drops of elution, collected with a centrifuge tube), add 1 drop of buffer after the Shakers for inspection.
Loading 500KG Logistics Rolling Container Trolley Features Model NO. RCT001 Material Steel Type Rolling Container Introduction Corrosion Protection Equipment Usage Warehouse Transport Cargo, Hotel Transportation Certificate CE,ISO 1. Fold, Nestable 2. Galvanized electro zinc ...
Throughout keeping pallets single-deep, providers can get to any kind of pallet anytime, without having to shuffle share close to. This particular systems will save a person period, as well as is ideal for the systems exactly where you possess just a few pallets for each ...
We are professional side lift forklift trucks supplier and factory in China. We can produce the product according to your requirements. TD Series side load forklift electric truck, rated load capacity: 2500kg, lift hieght:7200mm, used for long material transportation; 1. The ...