GDDZ Insulating Gloves Leakage Current Testers

Packaging
N/A
Delivery
15 Days
I.Application
  • GDDZ insulating gloves and boots is application to test leakage current,insulation aging,power frequency of insulating gloves and boots.
  • It can test 3 paris for each time and to read leakage current of each pair in order to find which one is unqualified.There are trundles in the bottom which make more convenience for moving.

II.Technical specification

1. Input voltage:AC220V 50Hz

2. Output voltage:0-30kV

3. Capacity:3kVA

4. Test units:6 units each time

5. Test data:Display and print voltage data and leakage current data of each unit

6. Overcurrent protection;Overvoltage protection;User-defined time setting,display voltage data and leakage current data

7. LCD display with print

8. Accuracy:Voltage ±2%(±3 digits) Current±2%(±3 digits)

9. Weight:control unit 12kg test bench 60kg