Natural or Propane Gas-Fired Boilers by Dunkirk

PLYMOUTH
STEAM II
NATURAL OR PROPANE
GAS-FIRED BOILERS

An ISO 9001-2000 Certified Company
Dunkirk Quality
Since 1928, American-made Dunkirk
Boilers have been leading the industry
in value and reliability with innovative
designs and premium quality
components. Assured performance
has placed Dunkirk quality at the top
in trusted reliability (99.91%*).
Every gas boiler we manufacture is test fired prior
to shipment. This boiler is certified by C.S.A. in the
United States; heat exchangers by ASME; and
efficiency ratings by the Hydronics Institute.
The Plymouth Steam II Boiler by Dunkirk offers
the best combination of heating comfort,
efficiency, reliability... and affordability, making
it one of Americas Hottest Boiler Values.
Heating Efficiency
The high efficiency of the Plymouth steam
boiler renders outstanding performance
and low operating costs.
Electronic Ignition
(Option) Pilot is lit automatically and stays lit
only when needed, eliminating fuel waste.
Integral Draft Diverter
Dunkirk utilizes built-in draft diverter
technology that is factory designed to protect
against harmful carbon monoxide back drafts.
Unlike competitor diverters erected in-field,
Dunkirk eliminates any installation guesswork
to ensure your familys safety.
Effikal Vent Damper
Automatically closes when the unit turns off,
preventing heated air from escaping up the
chimney. Effikal provides the strongest vent
damper warranty in the industry.
Titanium
Burners
Dunkirks exclusive
high-tech titanium
composite burners
resist corrosion and
oxidation while withstanding
more heat
than conventional stainless steel or aluminized
burners. They provide superior strength and
longevity and are backed by a full 3-year warranty,
triple the industry standard.
Cast Iron Sections
& Push Nipples
Dunkirk utilizes cast
iron to construct
the boilers heat
exchanger to provide
heat transfer, reliability
and strength. Since like
materials expand and contract in the same
proportion during heating and cooling,
cast iron push nipples and sections produce
stronger, more water-tight seals than steel
push nipples or rubber gaskets.
Easy Installation
Surprisingly compact, the Plymouth Steam II
Boiler fits in tight spaces and is supplied
assembled, with controls that are accessible
and completely wired. Piping is also at hand
for easy connection to the system.
Easy Maintenance
Low water cutoff is electronic, therefore,
results in minimal homeowner maintenance.
Controls are easily accessible without having
to remove the jacket, and our standard
controls are readily available, making Dunkirk
Boilers easy to service.
PLYMOUTHSTEAM II
NATURAL OR PROPANE GAS-FIRED BOILERS
Efficiency as High as 82.7%
DUNKIRK
99.91%
RELIABILITY
Strongest
Warranty in
the Industry
Dunkirk backs all
of its residential cast
iron steam boilers with a
full twelve year warranty
covering the entire heat exchanger.
Most competitors warranties cover
heat exchanger sections only and most
last for 10 years.
* Data on file - Dunkirk Boilers
FEATURES & BENEFITS
PLYMOUTH STEAM STANDARD EQUIPMENT
P(V) SB SERIES
STANDARD EQUIPMENT
Assembled boiler with insulated jacket
Two 2-1/2" supply tappings and two 2-1/2" return tappings.
Integral draft diverter built into jacket
24 volt, 40VA transformer
Pressure limit control
Electronic probe type low water cut off
Flame rollout safety shut-off fuse link and blocked vent
safety shut-off switch with spare fuse link included
Sight Glass Water Level Gauge
Steam pressure gauge
3/4" boiler drain valve
15 lb. ASME pop safety valve
Two 2-1/2 square head pipe plugs to plug unused supply
and return tappings
Vent damper
Complete installation instructions
Completely installed and wired gas control systems with
burners and manifold, consisting of:
Titanium composite burners
Automatic redundant combination gas valve, 24 volt
ELECTRONIC IGNITION ONLY:
Intermittent Pilot Control, continuous re-try,
100% shut off
Combination pilot burner/electrode/flame sensor
STANDING PILOT ONLY:
Pilot burner & thermocouple
OPTIONAL EQUIPMENT
Combustible floor plate 14614031 for 3-6 section;
14614032 for 7-9 section
Electronic Water Feeder
Natural to propane conversion kit (when ordering kit,
please provide serial number of boiler to be converted)
?heat transfer,
reliability and strength.
Electronic or
Standing Pilot Ignition
Optional electronic ignition
automatically lights the pilot
only when needed,
eliminating fuel waste.
Titanium
Burners
Dunkirks exclusive burners
provide greater resistance to
corrosion and oxidation.
Withstands 15% more heat
than conventional burners
on competitive units.
Pressuretrol
This operating control
prevents the boiler from
building pressure levels
beyond recommended
limits. Will shut down
the boiler if necessary.
Transformer
This receives the 120 volt
power from the buildings
electrical service and steps
it down to 24 volt power.
Water Sight Glass
Allows for easy viewing of
the boilers water level.
Low Water Cut-Off
Electronically monitors the
water level in the heat
exchanger shutting the
unit off if the water level
is too low.
Baked Enamel
Steel Jacket
Factory installed insulation
keeps off-cycle heat losses
W/DAMPER
NUMBER
OF
SECTIONS
AGA
INPUT
MBH
HEATING
CAPACITY
MBH
NATURAL GAS PROPANE GAS DIMENSIONS
PVSB
W/DAMPER
PSB
W/DAMPER
A.F.U.E.
Plymouth Steam II
FLUE
DIAMETER
"A"
WIDTH
NET
I = B =R
MBH
NET
I = B =R
SQ.FT. EDR
AGA
INPUT
MBH
HEATING
CAPACITY
MBH
NET
I = B =R
MBH
NET
I = B =R
SQ.FT. EDR
The ratings marked Net I=B=R Ratings represent the heat available to
the radiation or terminal units. The Net I=B=R Ratings shown are based
on an allowance of 1.33 in accordance with the factors shown in the
I=B=R Code as published by The Hydronics Institute.
Selection of boiler size should be based upon Net I=B=R Rating being
equal to or greater than the installed radiation in square feet EDR.
Consult manufacturer before selecting a boiler for installations having
unusual piping and pick-up requirements.
These boilers may be installed on combustible flooring when placed
on combustible floor plate.
These gas-fired boilers are sectional cast iron boilers design certified
by C.S.A. in the U.S. for use with natural gas and propane gas. They
are constructed and hydrostatically tested dEngineers) Boiler And Pressure Vessel Code Section IV standards for cast iron
heating boilers. They are capacity rated in accordance with the code of
The d.
 CUT-OFF
TRANSFORMER
GLASS
GAUGE
24"
2-1/2"
4-3/4"
26-1/2"f
S86
GAS
VALVE
?
Tested for 50 lbs.
ASME Working Pressure
 

  • Country:United States
  • telephone:1-634-4700
PLYMOUTH
STEAM II
NATURAL OR PROPANE
GAS-FIRED BOILERS
America'sHottestBoilerValue
*Your name:
*Your Email:
*To:Vincent's Heating and Cooling
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...

Veda Harvest Natural Stretch Mark Cream for Women & Men

Discover the path to beautifully smooth, supple skin with our RevitalizingStretch Mark Cream ...

Come From Veda Harvest

Natural Allergy Relief Supplement - 90ct

NAR™ a natural, non-drowsy approach to reducing the symptoms of allergies. Formulated with Traditional Chinese Medicine extracts created to reduce the debilitating symptoms of allergies. We are one of the best Natural Allergy Relief Supplements on the ...

Come From Rob Keller MD®

Natural Allergy Relief Supplement - 90ct

NAR™ a natural, non-drowsy approach to reducing the symptoms of allergies. Formulated with Traditional Chinese Medicine extracts created to reduce the debilitating symptoms of allergies. We are one of the best Natural Allergy Relief Supplements on the ...

Come From Rob Keller MD®