The condensing boiler includes a heat pipe-type air heater and an economizer to retrieve the hidden heat from discharged gas and vapor and to improve the energy efficiency by more
than 100%.
|
|
|
|
This all-in-one type equipment includes a fan, a water pump, a control panel and a continuous blow device. Simple on-site works.
|
|
|
|
A simple structure and easy cleaning, inspection and maintenance. In particular, it is simple work to replace the smoke tube.
|
|
|
|
The air preheater and the economizer attached to the main body saves installation space and costs and guarantees high performance. Depending on the condition of the site, you may
select just one of the air preheater or the economizer.
|
|
|
|
|
|
Model
|
B&B-C
|
100
|
150
|
200
|
250
|
300
|
350
|
400
|
450
|
500
|
600
|
700
|
800
|
1000
|
1200
|
1500
|
Rated evaporation
|
/hr
|
1000
|
1500
|
2000
|
2500
|
3000
|
3500
|
4000
|
4500
|
5000
|
6000
|
7000
|
8000
|
10000
|
12000
|
15000
|
Gas flow
|
kg/
|
10~16
|
Gas flow
|
%
|
94,(99~100)
|
Rated evaporation
|
|
17
|
23
|
26
|
32
|
39
|
47
|
54
|
60
|
68
|
79
|
94
|
109
|
134
|
161
|
200
|
Fuel con-
sumption
|
B/C
|
/hr
|
78
|
119
|
160
|
200
|
240
|
279
|
319
|
359
|
399
|
479
|
558
|
638
|
798
|
957
|
1196
|
LNG
|
N/hr
|
64
|
97
|
130
|
162
|
195
|
227
|
260
|
292
|
325
|
389
|
455
|
520
|
650
|
780
|
975
|
Valve
|
Main vapor
|
A
|
65
|
80
|
80
|
80
|
80
|
100
|
100
|
125
|
125
|
125
|
150
|
150
|
200
|
200
|
200
|
Safety
|
A
|
25
|
40
|
40
|
40
|
40
|
40.25
|
40.25
|
40x2
|
40x2
|
40x2
|
40.50
|
50x2
|
50x2
|
65.50
|
65x2
|
Water supply
|
A
|
25
|
25
|
25
|
25
|
25
|
40
|
40
|
40
|
40
|
40
|
50
|
50
|
50
|
50
|
65
|
Water drainage
|
A
|
40
|
40
|
40
|
40
|
40
|
40
|
40
|
40
|
40
|
40
|
40
|
40
|
50
|
50
|
50
|
Pressure meter
|
A
|
25
|
25
|
25
|
25
|
25
|
25
|
25
|
25
|
25
|
25
|
25
|
25
|
25
|
25
|
25
|
Water level meter
|
mm
|
220
|
220
|
220
|
220
|
220
|
280
|
280
|
280
|
280
|
280
|
280
|
280
|
280
|
280
|
280
|
Fuel
|
B/C
|
A
|
20
|
20
|
20
|
20
|
20
|
20
|
25
|
25
|
25
|
25
|
25
|
25
|
25
|
32
|
32
|
LNG
|
A
|
25
|
40
|
40
|
40
|
40
|
40
|
40
|
50
|
50
|
50
|
80
|
80
|
80
|
80
|
100
|
Boilers weight
|
Ton
|
2.25
|
2.98
|
3.27
|
3.52
|
3.65
|
3.71
|
5.44
|
5.67
|
5.98
|
6.50
|
7.05
|
7.58
|
8.45
|
9.94
|
11.7
|
Quantity
|
|
1.43
|
1.63
|
1.85
|
2.10
|
2.45
|
2.52
|
3.05
|
3.24
|
3.45
|
3.79
|
4.12
|
4.35
|
6.05
|
6.49
|
7.4
|
Outlet gas duct
|
mm
|
200
x300
|
250
x300
|
250
x400
|
250
x500
|
250
x550
|
250
x550
|
300
x550
|
300
x600
|
350
x600
|
350
x700
|
400
x750
|
450
x800
|
500
x800
|
550
x900
|
600
x950
|
Chimney
|
mm
|
300
|
360
|
430
|
460
|
500
|
550
|
580
|
610
|
650
|
680
|
740
|
820
|
900
|
960
|
1050
|
Installa-
tion exterior
|
Width
|
mm
|
2100
|
2190
|
2290
|
2320
|
2370
|
2400
|
2560
|
2630
|
2670
|
2720
|
2850
|
2975
|
3125
|
3225
|
3295
|
Depth
|
mm
|
3360
|
358/0
|
3800
|
3920
|
4035
|
4300
|
4620
|
4670
|
4760
|
4840
|
5070
|
5280
|
2945
|
6200
|
6670
|
Height
|
mm
|
1980
|
2050
|
2110
|
2170
|
2250
|
2300
|
2540
|
2630
|
2670
|
2870
|
3120
|
3395
|
3545
|
3645
|
3715
|
|
|
1. These specifications are subject to change depending on the customer's request and for the purpose of quality improvement.
2. Design pressure: 10kg/km2 (operational pressure: 8kg/km2)
3. Water temperature: 20,
4. Gas supply pressure is 2,000~4,000 mmA1
5. Includes a burner, a control panel, a pressuring insertion fan, a noise suppressor, 2 units of water pump and a drug
|