Technical parameters:1) Rated evaporation (BMCR): 35MT/h2) Rated vapor pressure: 3.82MPa3) Rated vapor temperature: 450oC4) Major feeding water temperature: 150oC5) Major feeding water pressure: 5.61MPa Boiler heat features (rated operating conditions):1) Guaranteed heat efficiency (upon heating quantity with low position):
Medium-temperature, medium-pressure or high-temperature cyclone separator fluidized-bed boiler complies with the main criterion of WB-35 / 3.82-M
Place of Origin: | China |
DHX circulation fluidized bed boiler has the range from low to high pressure, choosing the circulation fluidized bed firing technology. It has the remarkable effect on energy conservation and can suitable to various types of coal, especially to the low quality coal, the dealt ...
Come From Wuxi Zozen Boilers Co., LTD
It is the II-type arrangement of free-circulation single-cylinder water-tube boiler. Hearth is the membrane water-screen suspension enclosed structure. Water-cooled air chamber and water-cooled air distribution panel are used. Method of ignition: bed underneath. ...
Usage:Power Station Output:Hot Water Model Number:QXX14~116MW Brand Name:TAISHAN Place of Origin:China From 14 to 116MW ...
Come From Taishan Group Co., Ltd.