Floor Standing Boilers

The test pressure is 4,5 bar and the working pressure is 1 bar.

Pressure

 

Fan, thermostat, ash bucket and cleaning equipment, circulation pump.

Accessories

 

If the boiler range has got a fan, the control panel consists of pump onoff key,
fan onoff key, and thermometer.If the boiler range does not have fan the control panel
consists of pump onoff key and thermometer.The fan is controlled by the thermostat.

Control Panel

 

Insulation materials are different concerning the models and three different
insulation material is used such as special ceramics material, rock wool or
cheramics concrete.The durability for the cheramic insulation material is 3000 ?C.
While Linyitomat 15 and 25 has got a paddle box above the upper door,
the insulation material is rock wool instead of ceramical material.

Insulation Material

 

Linyitomat 15-25-40 and 60 consist of two doors.One for loading and the
second one is for ash cleaning.Linyitomat 80 consists of three doors.
The third one is for flame pipe cleaning.Each door made of metal sheet.

Doors

 

The required air for fire is supplied through mechanical thermostat for the models
Linyitomat 15-25-40 but for Linyitomat 60 and 80 it is supplied through fan.
Fan is given demounted as accessories with the boiler.In additon
Linyitomat 60 has an air valve that can be controlled manually.

Fan and Mechanical Thermostat

 

 

 

The water circulates through the buffles or plates up to Linyitomat 80.
The water circulates through the flame pipes from Linyitomat 80 up to Linyitomat 500.

Buffle and Flame Pipe

 

For all models the grill is made of cast iron.The grill is consists of part.It is possible to
change the grill against deformation.

Grill

 

The boilers ground is placed with an ash plate.A special kind of equipment is given
as accessories in order to clean the ashes.

Ash Plate

 

Linyitomat boiler is designed for lignite, wood and stone coal.The main difference between
from others is that the boiler is made of steel instead of cast iron and the construction
based on buffles.Thanks to the buffles the flame is easily moved out from the chimney
and the heat is kept for a longer time to stay inside.While the combustion chamber is
diminished by the lower fuel the higher efficiency is obtained.

LINYITOMAT 15-25-40-60-80

 

Solid Fuel Boilers

SOLID FUEL DOMESTIC TYPE BOILER

  • Country:Turkey