Hot Water Boiler

In monophase motors having troubles in start up and continual cycle condensator , during the start up the relays that starts up the auxiliary coil or the platinums with centrifugal

The proximity switch linked to the revolution axis  by measuring the revolution cycle of the motor  , it apprises the cycles of the motor step by step to the motor protection cycle.

Motor Protection System                                            : 

 

A Boiler with modulation card perceives the outside temperature and reaches the most productive combustion by consumpting less fuel.

The automatic ignition provides a comfort usage, By setting the weekly programme , the boiler is to be ignited and switched off at any time during the week . The user shall not need to deal with the ignition , setting the water temperature of the boiler and switching it off.

As it may be seen clearly from the figure , the ignition is achieved via an electrical resistance device that is located into a pipe and leading to the burn pot. The ignition temperauture needed for the fuel to be ignited is between 250 C and 400 C.

Automatic Ignition                                                        :

 

As the outside temperature decreases , the preset water temperature of the boiler is increased or conversely when the outside temperature increases , the preset water temperature of the boiler is decreased automatically.

 

As there are big differences between the temperatures occuring during the day time and night time ,the outside temperature is measured in order to modulate the water temperature of the boiler.

One of the other important modulation methods of the boiler is its ability to modulate itself according to the outside temperature as there are different countries from different locations of the world.

3. Modulation according to outside temperature ;

 

The less is the temperature of the gas given out , the more efficient the boiler is.

 

The flue temperature is measured via the help of a sensor connected to the electronic card. The maximum flue temperature is set on the electronic panel.  The boiler shall not exceed the set flue temperature  by regulating the fuel feeding time and the fan speed by this way not only the level of  fire is controlled but also the limit heat  and the emission given to the environment is kept.

2. Modulation according to the flue temperature ;

 

The operation capacity of the boiler is decreased one by one from % 100 to % 1 . In the modulation card , the fuel feeding and the fan speed of the system is shared to 100 steps. By decreasing one by one the capacity of the boiler is minimized from % 100 to % 1 . When there is a heat demand , the boiler itself automatically increases  the fuel feeding time and the fan speed.

 

Modulation card reduces the fuel feeding time , it purports that the amount of fuel transported to the burn pot is lesser. The minimum air amount that is required for an ideal combustion , is managed by reducing the fan speed ( by reducing the motor cycle of the fan )This means that  the air flow blown to the burn pot is decreased.As the oxygen amount for the combustion is decreased this breeds the fire level to be shortened.

 

-Low operating costs

-Comparing to the full operating systems , it consumpts less electricity

-Environment friendly ( as it extends less gas )

-Fuel saving

The advantages of the modulation system ;

 

Thanks to this , the combustion level is minimized and the boiler is not required to operate in full operation .

When we set the boilers Preset Temperature : 55 C , the boiler shall reduce the full operation capacity by itself . This is achieved by reducing the fuel feeding time and the fan speed automatically.

According to the position of the building , the capacity is choosen ( for instance ; a 40.000 Kcal/H Boiler ) When the heat demand is less in the building , the boiler is to be operated as a 20.000 KCal/H or 25.000 Kcal/H capacity.

1.Modulation according to the set boiler water temperature ;

This is an electronic part that providing the full automation of the boiler. The steps carried out by the modulation card are as follows ;

The operation principle of the modulation card

 

Thanks to the modulation card , this system operates with full automation.After having loaded the fuel to the bunker of the boiler , all processes automatically managed by boiler iteself and the ash is removed out to the ash box located in front of the boiler.

ELECTRONIC CARD WITH MODULATION , FULLY AUTOMATIC IGNITION , DOUBLE AUGER FEEDING MECHANISATION AND SYSTEM WITH ASH REMOVAL

 

Kozlusan Hot Water Boiler

  • Modulation:Optional
  • Ignition:Yes
  • Color:Red
  • Type:Once Through
  • Style:Vertical
  • Pressure:Low Pressure
  • Structure:Water Tube
  • Usage:Households, Offices, Hospitals, etc
  • Output:Hot Water
  • Fuel: Wood pellet, olive husk, agropellet, stra...
  • Country:Turkey
  • telephone:90-236-4272313
Package: Euro Pallet,Wooden Crate
Payment Terms: L/C,T/T
Color: Red
Type: Once Through
Style: Vertical
Pressure: Low Pressure
Structure: Water Tube
Usage: Households, Offices, Hospitals, etc
Output: Hot Water
Fuel: Wood pellet, olive husk, agropellet, straw pellet
*Your name:
*Your Email:
*To:Kozlusan
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...

R hot water centrifugal pump

R-type hot water circulation pump is a single-stage single suction and two-stage single suction cantilever centrifugal pump, suitable for metallurgical, power plants, chemical and other departments, used for conveying high-pressure hot water below 250 ℃ without solid ...

Come From Kenshine Pump And Valve MFG Co.,LTD

HOT WATER FAUCET

HOTEC hot water tap for bathroom, made out of a wearable, corrosion-resistant and heat-resistant brass, great in durability and reliability. The electric quality brass hot water tap bathroom fits almost any washroom and facility, coming out hot water quickly to cleaning hands, ...

Come From Hangzhou Hotec Cleaning Technology Co., Ltd.

EBICO EC-GR Ultra Low NOx Hot Water Boiler Burner

Model Output capacity (KW) Gas consumption (Nm3/h) Specifications of boiler (T) EC1GR 850 85 0.5/1 EC2GR 2000 200 2 EC3GR 3000 300 3 EC4GR 4800 480 4/5 EC5GR 6800 680 8 EC6GR 9500 950 10/12 EC7GR 13000 1300 15 EC8GR 17000 1700 20 EC9GR 20000 2000 25 EC10GR 24500 ...

Come From Ebico (China) Environment Co., Ltd.