7. The efficiencies listed in the date sheet are for rated output , voltage and speed , and include excitation lose , excluding that of separate ventilating fans.
6. A marked earthing terminal is provided forth motors.
5. For frame size Z4-315,Z4-355,Z4-400 and Z4-450 , compensating windings are provided . For frame size Z4-250 and Z4-280 the motors are feasible with a compensating winding too.
To assure the reliability of insulation of excitation system , the motor must be protected against self induced voltages by a release resistor connected in parallel with the excitation circuit of the motor is interrupted . At rated field voltage the value of shunt resistor is about seven times filed winding resistance (cold state) . While the field voltage is higher than nominal voltage , the value of shunt resistance may be lower than seven times field resistance , otherwise higher than seven times .
4. Separate excitation is the basic excitation type of the motors .Nominal field voltage:180v.Other excitation voltages are also acceptable on request .Forced excitation is allowed with the voltage of less than 500v.When a motors is normally running ,its excitation current must not be higher than rated excitation current.
The torque can be remained constant by reducing speed via armature voltage weakening below raced value .It is stipulated that armature speed range can be down to the lowest 20r/min at constant torque and stable running.
3. Rated speed:3000,1500,750,600,500,400,300 and 200 r/min ,totally nine grades . Decrease armature voltage to make speed regulating under constant torque ,lowering down field voltage to make speed regulating at constant output .Speed regulating range :see technical date(Table 2).The given multiple of load to rated load of different speed range.
2. Standard rated voltage :160v or 440v,values for 220v,440v,and 660v or other voltage may be derived on request.
f. Performances of motors all comply with State Standard GB755.Fundamental technical rules for electrical machines.
e. Armature and field circuits for motors may be either operated on static rectifier controlled supplies ,or form dc generator.
d. Duty :Continuous(S1)
c. The working environment should not be acidic, alkaline or other corrosive effect of gas insulated
b. Cooling air temperature maximal 40;
a. Altitude above sea level maximal 1000m
1. Data listed in the technical data sheet should be employed under the following conditions;
Electrical Performance
The motors can be lastingly operated form fully controlled three-phase bridge without a smoothing reactor .Motors for 160v may be operated on single-phase bridge thyristor ,in that case ,a smoothing reactor ,whose inductance is specified in the relevant technical date ,should be inserted in the armature circuit to reactor ripple current.
The motors possess the features of small size ,good performance ,light weight ,large output ,high efficiency and reliability ,being able to match the current international advanced level.
The motors are class F insulated ,with reliable insulating construction and impregnating process , ensure stable dielectric performance and excellent heat dissipation.
Performance and technical requirements of the motors can be checked in accordance with IEC34-1 Standard of the International Electro technical commission ,or DIN57530 Norm of the Deutsche Industries-Norm.
Outline and mounting dimensions of the motors comply with IEC72 Standard , except for the axial distance between the mounting holes.
Z4 series DC motor is widely used as various types of mechanical transmission source, such as the metallurgical industry rolling mill drive, metal cutting machine tools, paper, printing, textile, printing and dyeing, cement, plastic extrusion machinery, etc.
Features and Uses
Z4 series DC motor is widely used as various types of mechanical transmission source
Power: | DC |
Speed: | Variable Speed |
Function: | Driving |
Protect Feature: | Enclosed |
Usage: | Industrial |
Model Number: | Z4 |
Brand Name: | JSDY |
Place of Origin: | Jiangsu China (Mainland) |
DC Motor Peristaltic Pump DC Motor Peristaltic Pump is the most important part of a simple fluid transfer device. DC peristaltic pump is responsible to drive the suitable tubes to reach a specific range of flow volumes with the help of a positive and a negative power supply. We ...
Acrel DJSF Series modbus dc power meter with double channels DC input is mainly designed for telecom base station, DC charging pile, solar photovoltaic and other applications. This series of meters can measure voltage, current, power and positive and negative energy in the DC ...
KE300A-04 single phase inverter drive, based on the world\'s leading speed sensorless high-performance vector core control algorithm, combined with the unique start-up and control requirements of variable speed single phase motor, using a new magnetic flux vector control ...
Come From Shenzhen MICNO Electric Co., Ltd.