Reliable press system
Guarantees the pressure automatically, slow load, speed adjustable, unique pressure column seal structure.
Advanced automatic control and safe link
Uses the computer realization temperature, movement process completely automatic control, PLC realizes the safety interlocking, has overpressure, ultra warm,
water temperature excessively is high, vacuum pump overloads, lacks the equal acousto-optics to report to the police and the interconnection ability.
Reliable high effective vacuum
Uses the advanced vacuum unit, the realization perfect vacuum and achieves the low rate of gas leakage request.
|
Furnace body part: The furnace body material structure, the endophragm is the stainless steel, the outer wall is the ordinary carbon steel, the inside and outside
intermural for the circulation water cooling; The pressure column is the water cooling structure, the diameter and the traveling schedule by the user basis use decision, the speed
adjustable, the pressure column may withdraw from the heat preservation area; The furnace body structure is suitable for the vacuum thermo-compression and the atmosphere
thermo-compression two kinds.
Vacuum system: According to user's operation requirements, use many kinds of dispositions, is generally: Mechanical pump Roots vacuum - proliferates the pump, the limit vacuum
degree may reach to 10-3Pa, the pumping air speed be possible to act according to the chamber size, the thermo-compression material puts the spirit vigorously, selects the
different disposition.
Power source: The heating way is divided the intermediate frequency induction heating and the resistance heating, the power source merit is 45KW-200KW, the heating temperature 400
C-2300 C
Automatic control: The temperature control and the elevation of temperature speed control selects the island electricity/island Yan measuring appliance, establishes voluntarily
warm controls the curve manually, the realization, the automatic two use way; The temperature measurement may use the tungsten rhenium thermoelectricity occasionally double color
temperature idea according to user's thermo-compression temperature; The equipment disposition pressure transmitter, the position transmitter, can the actual pressure hypothesis
and the control, the pressure column and the displacement distance may the measuring appliance demonstrate that, the above control may print the record automatically.
|