Multi-function input - thermocouples, resistance thermometers - current and voltage signals ?Display for process value - LED display, 4-digit in H or K - accuracy ?0.2 % of end value ?1 digit ?Other features - self monitoring - sensor monitoring - cold junction compensation - hold-function Specifications according to data sheet TE 88.06 Demensions 96x48x110 m.m. Input multi-function input Description The new attachable indicator model 907.15 507 provides an ideal solution for a local readout with simultaneous single transmission. Due to its universal programmability and simple mounting it is possible to retrofit the attachable the attachable indicator even to pressure transducers which are already in use. No additional power supply is required. The indicating range can be adjusted by means of flush-mounted keys below the front cover. The operator is guided through all steps of the program required by a locally arranged menu with simple characters on the LCD display. Damping of the readout is possible in three steps ensuring precise readability of the indicating value in case of pulsation or if pressure peaks are occurring . The Model A-IAI attachable indicator has been developed for hazardous areas applications requiring certified intrinsic safety of hazardous areas applications requiring cerfified intrinsic safety of class EEx Ib IIc T4 to CENELEC/DIN/BASEEFA standards. The attachable indicator can be combined with the pressure transmitter model 892.X3.5XX and with the line transformer model 903.30.700 to enable the use in intrinsic areas of zone 1. The attachable indicator is provided with an integrated self-diagnosis circuit monitoring the perfect function of the essential parts of the indicator continuously. The integrated self-diagnosis together with error messages for sensor rapture and upper or lower deviation to the range ensure a high operating safety. The sturdy and compact plastic case meets the requirements of weather protection according to IP 65, making the instrument ideally suited for a great variety of industrial applications. Specifications Model 907.15.507; Model A IAI-1 Disply -Principle -Range -Accuracy Pick-up-rate Error Message % 1/s 4-digit,LCD 10 mm high figures -1999...+9999 +0.2 measurements, damping in 3steps selectable FE1: exceeded range FE2: below range Scale adjustment menu driven, start and end of measuring range as well as well decimal point can be university set by means of keys below the front cover. Electrical connection Power supply Voltage drop Max. current rating V mA to pressure transmitter with 4... 20mA output and plug according to DIN 43 650, polarity-free mounting not required, because the attachable indicator is supplied by the 4... 20mA-loop 3 60 CE-conformity tested according to EN 50 081-1 and EN 50 082-2 Permissible temperature for ambient storage Temperature influence on the display Weather protection Permissable relative humidity of air C (F) C (F) % % 0... +50 (+32... +122) {extended ambient temperature range on request} -30...+80(-22...+1796) 0.1/10K IP 65 per EN 60 529/IEC 529 < 90, non condensing protection certification Conformity specifications: power supply short circuit rating power limitation ambient temperature DC mA mWm C model A-IAI-1 EEx ib IIc T4 9...28 V 100 800 -20... +60 refer to certificate of conformity PTB Nr, Ex 97.D.2250 for additional data Case material Weight Dimensions Scope of dilivery` g ABS, front window made of polycrabonate approx, 80 see drawings attachable indicator, blue profile packing, fastenig-screw, manual Items in curved brackets {} are optional extras for additional price.
Multi-function input - thermocouples, resistance thermometers - current and voltage signals |
RMS is a direct measure of the power or heating value of an AC voltage compared to that of DC ...
Come From ZENITH INSTRUMENTS
NB!! A CT must always be used when measuring current for isolation purposes. ...
Come From ZENITH INSTRUMENTS
Vaisala HUMICAPHumidity Indicator Model:MKM-VIWI0013 Cat.No: Humidity measurement Measurement range ...
Come From BRIMSTONE INC