3 Value of previous version
2 Conditions: suction pressure < 10 mbar, DI water, settings mp-x: 100 Hz, 250 V, SRS, the max. flow rate will be reached after a few minutes of operation time.
1 Typical values. Values can vary under application conditions. Content is subject to changes without notice.
550 mbar +/- 15% (100 Hz)
Max. back pressure
6 ml/min +/- 15% (100 Hz)
Max. flow
Water
Liquids
on request
Max. back pressure
on request
Max. flow
Gases
(values defined with mp-x: 250 V, SRS):
Typical values of flow and back pressure for selected media
mp-x and mp6-OEM
Suitable evaluation controller
polyphenylene sulphone (PPSU)
Materials in contact with media
IP33
IP code
5000 h 3
Life time
0 70
piezo driven micropump: small, made from plastics; simple, durable, reliable; wide performance spectrum; low energy consumption.
Pressure: | Low Pressure |
Standard or Nonstandard: | Standard |
Power: | Electric |
Usage: | liquids and gases |
Structure: | Diaphragm Pump |
Theory: | piezo membrane micro pump |
Place of Origin: | Germany |
Structure:Diaphragm Pump Small Light weight Self priming Bubble tolerance Liquid/Water Gas Air Membrane Cooler Medical dosing Printer Ink Perfume Alcohol ...
Come From Microjet Technology Co., Ltd.