ESCO : Pump

Home > Pump > PIMS
 
Abstract : Performance Monitoring and Evaluation System for Industrial Pump Systems
 
Applied Technology : Pump Efficiency Measurement with Thermodynamics
ComparisonsHydraulic MethodThermodynamic Method
Measuring Parameters Flow rate, Pressure, Power Temperature, Pressure, Power
Advantages and Disadvantages - Difficult to measure flow rate with accuracy.
- Difficult to evaluate efficiency due to inaccurate flow measurement
- Easy to measure flow rate using temperature and pressure measurement
- Easy to evaluate efficiency thanks to accurate flow measurement
 
Diagram


 
Benefits
 - Reduce electricity by optimizing operation pattern.
 - Prevent unnecessary pump maintenance
 - Early warning of poor pump performance
  • Country:South Korea
  • telephone:82-82220822470
Abstract : Performance Monitoring and Evaluation System for Industrial Pump Systems
*Your name:
*Your Email:
*To:ESCO Professionals Co., Ltd
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...