See also:
The SO-3 barrier fluid reservoir canto be used as standard for majority applications.
The system can be fitted with instrumentation and control for automatic checking of mechanical seal performance and pump shutdown in case of mechanical seal failure. The instrumentation and control
version of SO-3 can additionally include a level sensor, a pressure switch, and a temperature sensor. Sensors and switches are either intrinsically safe or explosion proof depending on customer's
order.
The SO-3 barrier fluid reservoir is designed to contain barrier fluid for a tandem or double mechanical seal, to provide its cooling and to control mechanical seal performance. The SO-3 barrier fluid reservoir can be used with API Plans 52 or 53 as per API682. For operation under the API 53 Plan, fluid make up manual pump NRP with the installation kit should be additionally specified.
See also: The rare feature of this buffer fluid reservoir is that it can be disassembled for cleaning if the heat exchanger gets fouled. The heat exchanger has straight tubes that can be mechanically cleaned. The reservoir can be fitted with instrumentation and control for ...
Come From TREM Engineering