The C700BW body is fabricated from the highest quality of forged bar stock ASME-SA479-316SS. Pressure rating is the same as Sch 160 316 SS pipe.
The NRC has also cautioned against using torturous path valves or devices because of a plugging potential view the . Our diffusers are not torturous path devices. We design them to minimize the potential of plugging.
The Nuclear Regulatory Commission notice 98-45 has warned of flow induced vibration damage that can be caused by condensate flow in single-hole, single orifice let-down systems. View this report on the web site.
Another important benefit of a multi-hole diffuser is that the energy of the discharge jets is dissipated in a much shorter distance than the jet from a single orifice. This would prevent damage to nearby elbows, etc.
The Control Valve should be located upstream of the diffusers. For on/off control situations, the control valve should take approximately 20-30% of the pressure drop and the diffusers take the rest of the drop. For modulating control situations, the control valve should take 60-70% of the pressure drop and the diffusers take the rest of the drop. This will greatly reduce the initial cost and the maintenance cost of the control valve.
One of the most respected hydraulic laboratories in the country has validated the performance for our multistage diffuser design for the pump recirculation system for a nuclear power plant.
Because of the high-pressure drops involved with these high temperature liquid streams, the fluid flashes and/or cavitates at the exit of the control valve. This erodes both the control valve and the downstream piping. In addition the resulting pounding as the fluid implodes causes unacceptable noise and vibration of the piping. In some cases, the control valve, the downstream piping and the hangers must be replaced in a matter of months.
These diffusers can be used for any flow-restriction orifice service.
For example, two of the most difficult flow control problems in a power plant are the control of the Boiler Feed Pump recirculation and boiler feed pump warm-up systems. Another example is the boiler blowdown system.
The C700SW diffuser is the Butt-weld version of CU Services LLC's family of high-pressure-drop diffusers. It can be used individually or as a multi-stage orifice plate system of two or more units placed in series to eliminate the damage that is caused by control valve cavitation.
Model C700BW Diffuser System
NO MAINTENANCE! FIVE YEAR WARRANTY!
Model C700BW Diffuser System NO MAINTENANCE! FIVE YEAR WARRANTY! |