AQB 15-20 SEER HEAT PUMP

AQB 15-20 SEER HEAT PUMP
  • Indoor Unit shall be constructed from Anti Bacterial HIPS, certified to UL94 V0. Closed cell foam shall be used to insulate against sweating. The Outdoor unit shall be constructed from galvanized steel with a baked on powder coated finish for durability

Construction
Indoor Unit shall be constructed from Anti Bacterial HIPS, certified to UL94 V0. Closed cell foam shall be
used for insulation. The Outdoor unit shall be constructed from galvanized steel with a baked on powder
coated finish for durability
Heat Exchangers
The heat exchangers shall be manufactured using diamond cut aluminum fin mechanically bonded to copper
tubes. All heat exchanger fins shall be coated with an hydrophilic and corrosion resistant finish
Refrigerant Control
Refrigerant Control shall be by a capillary tube located in the Outdoor unit, refrigerant shall be environmentally
friendly R410A
Compressors shall be a hermetically sealed rotary type with external Overload protection and suction
accumulator
Condensate Removal from Indoor Unit
Shall be accomplished via the standard 18" length Drain hose, can connect to 5/8" ID or 3/4" OD PVC tubing
Fans
The indoor unit fan shall be molded from HIPS, statically and dynamically balanced for quiet operation.
Multiple fan speeds shall allow the user to select the required airflow. An auto swing louver can be used to
either oscillate or be stopped in a user selected position. The condenser fan shall be a propeller type with a
single or dual speed motor
Controls
Control shall be operated via a hand held wireless remote control with a range of 20ft
Unit shall be able to operate in the following modes : Auto, where a default set point of 74 DegF (user
adjustable by +/- 2 DegF). In Auto mode the Indoor unit shall determine the optimum fan speed.
Cool mode shall feature user selected room temperature and fan speed
Dry mode shall be akin to the cooling mode, except the Indoor fan speed shall be factory preset for optimum
de-humidification
Fan mode shall just feature operation of the Indoor fan at a user selected speed
The unit shall feature a real time timer feature allowing a single on or off operation to be programmed for a
specific time. A sleep feature shall reduce indoor airflow for quieter nighttime operation
Room temperature shall be sensed by a thermistor mounted on the Indoor unit coil, directly in the return air
flow stream. Indoor coil temperature shall be monitored to prevent the Indoor coil from freezing up due to
lack of airflow or a refrigerant loss
All units shall feature Auto restart in the event of a power failure.
Control voltage is line voltage 115V or 208/230V depending upon unit power supply
QUI-SBQSCE-001
QSCE-091, QSCE-121, QSCE-181, QSCE-241
HIGH WALL COOLING ONLY DUCTLESS MINI SPLITS

try heat pump    to get through more products

  • Country:United States
  • telephone:1-800-728-7777
Indoor Unit shall be constructed from Anti Bacterial HIPS, certified to UL94 V0.
*Your name:
*Your Email:
*To:Dubuque Supply Company
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...