Mixing Valve

There are many methods of controlling colonization of Legionella bacteria. However, a widely accepted and preferred method is to maintain the hot water system storage temperature continually at or above 60C. Unfortunately, the elevated temperature necessary to minimize the growth of and kill Legionella bacteria has the potential to cause serious thermal shock and scalding injuries.

It can find an ideal host environment of warm water temperatures (40-46Celsius degree), stagnant water areas (storage tanks and dead-end piping legs) and ample food sources (sediment, scale, deposits and biofilm). Under these conditions Legionella can rapidly colonize, forming higher concentrations that can pose the public health threat of Legionnaires Disease.

Legionella is the bacteria responsible for Legionnaires Disease, an acute bacterial infection of the lower respiratory tract. This bacterium was first identified in 1977 by the Centers for Disease Control as the cause of an outbreak of pneumonia that caused 34 deaths at a 1976 American Legion Convention in Philadelphia. Pontiac Fever is a less severe, non-pneumonia, flu-like disease that is associated with and likely caused by Legionella bacteria. Legionella is a fairly common water bacteria and has been found to exist widely in many surface water sources such as; lakes, rivers, streams and ponds. It can also be found in ground water sources and some soils. At the levels found in these naturally occurring sources it typically does not pose a threat to public health. When the bacterium enters a domestic water system

9. Relationsships between TMVs and Legionella:

 

j.   Prior to installation, provisions should be made to flush the piping of any debris or other foreign materials to ensure proper system operation

i.   If the ratio between two inlets is too large, one flow-limiting valve should be fixed at the side of higher pressure.

h.  The external check valves at inlets prevent cross-flow of hot&cold water when inlets pressure is not the same.

g.  After temperature setting, if inlets temperature or pressure fluctuates, outlet temperature variation is within +/-2 Celsius degree.

b. Install in accordance with markings on valve body. i.e. hot water inlet-marked H, cold water inlet-marked C

a.  All installations should be carried out by a Licensed Professional.

8. Installation Precaution:

Upon use of tempered water, a thermostat in the mixing chamber of the valve senses the outlet temperature. The thermostat automatically positions a seat assembly which controls the flow of hot and cold water supplied to the mixing chamber. If the mixed outlet temperature increases, the thermostat will expand moving the seat assembly to allow the cold water inlet port to open more fully and at the same time restricting the hot water inlet port. Conversely, if the mixed outlet temperature decreases, the thermostat will contract moving the seat assembly to allow the hot water inlet port to open more fully and at the same time restricting the cold water inlet port. In both cases the mixed outlet water temperature is automatically and continually maintained at the preset temperature within the tolerances of the valve. In the event of a cold or hot water supply failure, the seat assembly moves to an extreme position shutting off the hot or cold inlet water port. A mechanical adjustment permits selection of the desired outlet water temperature within range of the valve.

7. How They Work?

f.    Prior to installation, provisions should be made to flush the piping of any debris or other foreign materials to ensure proper system operation.

e.  If the ratio between two inlets is too large, one flow-limiting valve should be fixed at the side of higher pressure.

d.  The external check valves at inlets prevent cross-flow of hot&cold water when inlets pressure is not the same.

c.  After temperature setting, if inlets temperature or pressure fluctuates, outlet temperature variation is within +/-2 Celsius degree.

b. Install in accordance with markings on valve body. i.e. hot water inlet-marked H, cold water inlet-marked C.

a.  All installations should be carried out by a Licensed Professional.

6. Installation Precaution:

Point of use mixing for wash hand basins, bidets, baths and showers in hospitals, schools, sport and leisure facilities, prisons and other public buildings.

5. Usage of TMVs

TMVs accurately control water temperatures for bathing, showering and hand-washing. They maintain pre-set temperatures - even if water pressure varies when other appliances are used. TMVs can be fitted under baths and basins, be part of shower fittings, or as a feature of exposed hot and cold water mixers.

They shut-off rapidly in the event of a hot or cold supply failure to prevent scalding or thermal shock.

A Thermostatic Mixing Valve is a valve that blends hot water (stored at temperatures high enough to kill bacteria) with cold water to ensure constant, safe outlet temperatures preventing scalding.

4. What is the thermostatic mixing valve?

e. Tamper-Proof Cap

d. Idea for Domestic Water Application

c. Extended Mix Temperature Range : 35-45 Celsius degree

b. Delivers Stable Mixed Water Temperature

a. Fail-safe on Hot or Cold Supply Failure

3. Features:

e. Connection : Inlets-M, Outlet-F

d. O-ring : EPDM

c. Spring : Stainless steel

b. Shutter : PPO

a. Valve body : DZR Brass P-CuZn40Pb2. Chromed Nickel.

2. Materials of Construction

h. Rated outlet flow: 0.9Cb.m./H (Same as 15L/Min)

g. Adjustment Accuracy : +/- 2  Celsius degree

f. Outlet Temperature range: 35-45  Celsius degree

e. Cold water inlet temperature range : 5-29  Celsius degree

d. Hot water inlet temperature range : 50-80  Celsius degree

c. Maximum working temperature :

Outlet Temperature Range: 35-45 Celsiusdegree
Idea for Domestic Water Application
Tamper-Proof Cap
Thermostatic valve
G1/2"

  • Port Size:G1/2", DN15
  • Outlet Temperature range:35-45 Celsius degree
  • Adjustment Accuracy:+/- 2 Celsius degree
  • Rated flow:0.9Cb.m./H (Same as 15L/Min)
  • Valve Body:Nickel-plated brass
  • Connection:Inlet-M,Outlet-M
  • Model Number:BXHS-15G-F
  • Brand Name:SYBX
  • Place of Origin:Liaoning China (Mainland)
  • Country:China (Mainland)
  • telephone:86-24-22510528,13898845136
Delivery Time: 5-45days
Package: Carton1 piece packaging(mm):150*87*52, small carton10 pcs package(mm):310*245*130, middle carton30 pcs package(mm):470*315*190, big carton
Supply Ability: 5000 Piece/Pieces per Month
Minimum Order Quantity: 20 Piece/Pieces
Payment Terms: T/T
Port: Dalian
Fob Price: US$18-400Dalian
Outlet Temperature range: 35-45 Celsius degree
Adjustment Accuracy: +/- 2 Celsius degree
Rated flow: 0.9Cb.m./H (Same as 15L/Min)
Valve Body: Nickel-plated brass
Connection: Inlet-M,Outlet-M
Model Number: BXHS-15G-F
Brand Name: SYBX
Place of Origin: Liaoning China (Mainland)
*Your name:
*Your Email:
*To:Shenyang Beixin Energy-Saving Equipment Co., Ltd.
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...

R610/R640/R650 Series China Self-operated Control Valve

A self-operated control valve, also known as a self operated pressure control valve or self operated temperature control valve, is an auto control valve that relies on the pressure and temperature of the medium flowing through the valve as an energy source to drive the self ...

Come From Utmost flow control technology Co., Ltd

Electric Ball Valve, ASTM A216 WCB, 4 Inch, 150 LB, API 6D

Product Item: Electric Ball Valve. Material: ASTM A216 WCB. Size: 4 Inch, DN100. Pressure: Class 150 LB, PN20. Design Standard: API 6D. For ...

Come From China Ball Valve Manufacturer Co., Ltd.

ASTM A182 F316 Ball Valve, API 6D, 4 Inch, DN100, 150 LB

Product Item: Ball Valve. Design Standard: API 6D. Body Material: ASTM A182 F316. Nominal Diameter: 4 Inch, DN100. Pressure: Class 150 LB, PN20. Working temperature: -29℃ to +120℃. Face to Face: ASME B16.10. Test and Inspection: API 598.For ...

Come From China Ball Valve Manufacturer Co., Ltd.