Test all sensors and repeat procedure for any sensor, if is necessary.
Maximum number of wireless sensors that can be coded by system is 10. But you can register countless wireless sensors by changing sensors ID.
2. Coding wireless sensors. (Registering wireless sensors with control unit)
Procedure to add a new sensor (remote controller/wireless door sensor, wireless PIR detectors) in the system:
- Plug off 12V supply from alarm system
- Plug on 12V supply at alarm system
STATUS light will be red for 20 seconds. During this time make sensors to work (press any button on remote controller, make PIR and gap sensors (move the two parts of door sensor) to work). They
will be recognized and coded in the system. After 20s system is ready to work when the Status light turns green.
Reset procedure:
- System must be disarmed
- Press reset button and keep it pressed
- Plug off 12V supply from alarm system
- Plug on 12V supply at alarm system again, alarm LED will have a brief flash
- Release reset button and let system LED to become green.
Now system is reset and back to factory settings.(the passwords is 1234)
1. Resetting the system.
NOTICE! Resetting the system all coded information and messages will be lost.
System will be loaded with basic factory settings. The passwords will be back to
the original default-1234. You must code/register all wireless sensors again after reset.
Advanced Instructions
a. 1# - set output 1(open collector) on
b. 1* - set output 1 off
c. 2# - set output 2(open collector) on
d. 2* - set output 2 off
e. 3# - set output 3(open collector) on
f. 3* - set output 3 off
g. 4# - set output 4(onboard relay) on
h. 4* - set output 4 off
i. 5#- set Text message (SMS) on (default)
j. 5*- set Text message off
k. 6# - set with voice
l. 6* - set voice off
m. 7# - set alarm siren to work (default)
n. 7* - set siren all time off (silent alarm)
o. 8#abcd# -set new PIN. E.g.: 8#8686# --set new PIN code at 8686.
Note: It is wise to change PIN code at first login in alarm system.
p. 9* - stop the siren and open internal microphone of alarm system, for audio
monitoring of the spot.
q. 9# - stop monitoring/listening-in and open the siren
r. 0# - arm the system
s. 0* - disarm the system
Call the alarm system. After one ring unit will answer and a beep will be heard.
You have to input a PIN and # at end for security purpose. Default PIN is 1234.
At first login, please dial 1234#.
NOTICE! This PIN code is for alarm system NOT for SIM card.
System responds with beep (digital voices are available for some areas) and now you can send several commands and change some settings.
Commands of the system:
Using a telephone or cell phone to make GSM Alarm system arm/disarm:
OUT1, OUT 2 and OUT 3: show the status of output 1,2 and 3. They can be used to three lights or other home appliances.
RELAY: The fourth LED. It shows relay status. There is a on-board relay inside. The Relay LED will be on when the relays two ports are closed.
ALARM: The fifth LED shows the working status of siren. If siren is triggered, the Alarm LED will be on.
MONITOR: When it is on, it means the system is in the status of listening-in.
STATUS: It shows the signal status. At the first beginning, it is red which shows that the system is searching for GSM network and it will turn green when it finds GSM network. At
this moment, the GSM alarm system is ready to work.
POWER: Power status LED. It will be on when the system is switched on.
If you use only kit sensors, system is ready to be power on.
Sensors and remote controls delivered in kit are already coded (registered) in the system by factory. Plug in DC 12V power supply in alarm system.
4. How to identify the LED.
3. Connect the siren.
2. Connect the antenna.
Attention! Be careful, do not over-tighten the nut or let it loose!
1. Insert SIM in alarm unit.
Press yellow point gently with a pencil tip. SIM tray will come out.
Put the SIM in it and insert in back.
Attention! Metal contacts of the SIM must be down. Check it to be inserted correctly in the unit.
Before insert SIM in alarm unit, using a regular mobile phone do the following steps:
- Set PIN code request to off.
- Delete all stored numbers
- Store only numbers desired for alarming (up to 5 numbers). Numbers must be inserted in order of calling. First stored will be first called, second stored will be second called and so on.
Attention! Be careful, do not over-tighten the nut or let it loose!
GSM receiving: 900/1800mhz, or quad-bands (850/900/1800/1900MHz).
Stand-by current:
GSM Alarm with SMS sending, auto-dialing 5 persons.
7 wire zones, 30 wireless zones
433mhz.
try gsm alarm to get through more products
Delivery Time: | 3 days for 500-unit order |
Package: | One set in one gift boxNeutral packing box in Englishcustomized design with any language are welcome |
Supply Ability: | 1000 Set/Sets per Week |
Minimum Order Quantity: | 10 Set/Sets |
Payment Terms: | T/T,Western Union |
Port: | Shenzhen or HK |
FOB Price: | US $65 - 70 |
Wireless Sensors: | PIR motion sensor, Smoke Detector, gas detector |
SOS: | Kids/elder protection |
Emergency help: | Panic button |
Security & Burglarproof: | Home Burglarproof alarm |
Usage: | House security, burglarproof |
Model Number: | GSM-M3A |
Brand Name: | UVI |
Place of Origin: | Guangdong China (Mainland) |