Operation Instruction
1)System setting arm:
When put off the key,after 5 seconds, beepr sound once to hint,10 seconds later
beeper sound once, system enter arming status, arming LED is lightling, system cut the power.
within arming status, if use key to put on the engine,but not using ID card to disarm, system
is beeper sound to hint.
2)System disarm:
when system is on arming sttus, use the ID card to disarm, beeper sound once, LED is not
lighting, if not put on the engine with key withiin 15 seconds, system enter arming status
automatically.
3)System halt:
On disarming status, put the key OFF to ON 5 times, beeper sound once, use the ID card to
connect receive coil, then system halt, when put off the engine, system not enter armiing status,
LED flashing once per 5 seconds.
4)System recovery:
On halt status, put the key OFF to ON 5 times, beeper sound twice, system cancelled halt status,
enter arming status.
5)Learning method:
On arming status, LED is lighting, put the pin shortness for 3 seconds, then put off, LED
is lighting, enter learning status; Use the ID card connect receive coil, learning once,
learning twice, beeper sound twice, ect. after 5 seconds, beeper sound once, system cancelled
learning status, s, only accept 5 ID card; if not learning within 6 seconds, system cancel
automatically; when canceling, beeper sound 3 times, means learning is fail.
6)Reset button:
If the system is abnormal, press reset button for 6 seconds, system disarmed.
RFID ID CARD ALARM SYSTEM