Conventional Heat Detector,Two or four-wire models,Advanced detection and discrimination algorithm,Easy installation,maintenance
. Product
features
o Two or four-wire models
o Advanced detection and discrimination algorithms
o Easy installation and maintenance
o Sleek low-profile housing design
o Durable sensor head, no need for replacement
o SMD circuit board design-satisfactory quality and reliability guaranteed
o Five years limited warranty
o Satisfactory quality and reliability guaranteed
. Options:
o AR (auto reset) function for security systems (optional for four-wire models)
. Heat sensitivity:
o Ceiling spacing: 50-feet rating for heat sensor
o Start-up current: 70mA maximum
o Alarm impedance: 100 ohms +3V maximum, 560 ohms +3V maximum (red LED open circuit)
o Reset voltage: less than 1V Reset time: less than one second
o Alarm indicator: continuously emitting red light Temperature range: -10 to 50 degree Celsius
o Remote output: 15mA maximum, diode gate
o Permissible current: 15mA maximum, diode gate, 80mA maximum
o Humidity: 0 to 95%RH, non condensation or icing
o Alarm contact: for four-wire NO or NC operation N/C (normal/close)-N/O (normal/open) selectable relay output
o Form A: 1.0A at 30V DC/0.5A at 125V AC
o Dimensions: 10 x 46mm with base Weight: 160g/set with base Dimensions (diameter x H): 100 x 46mm, with base Weight: 130g/set, with base
Conventional Heat Detector,Two or four-wire
Minimum Order Quantity: | 1 Piece/Pieces |
Payment Terms: | T/T,Western Union |
Port: | NINGBO |
FOB Price: | US $88 - 100 |
smoke detector: | fire alarm |
Usage: | Smoke |
Model Number: | 210103 |
Brand Name: | WANLIDA |
Place of Origin: | Zhejiang China (Mainland) |
Input Voltage: DC10-35V Static Current: not more than50uA Alarm Current: 40-80mA Operating Humidity: 10%-95%RH Operating Temperature: -10 Celsius - 55 Celsius Alarm Reset: Auto reset Alarm Temperature: Fixed Temp.: 57 Celsius/137F Rate-of-rise: 8-15 Celsius/Min LED Indication: ...
Input Voltage: DC10-35V Static Current: not more than50uA Alarm Current: 40-80mA Operating Humidity: 10%-95%RH Operating Temperature: -10 Celsius - 55 Celsius Alarm Reset: Power off reset Alarm Temperature: Fixed Temp.: 57 Celsius/137F Rate-of-rise: 8-15 Celsius/Min LED ...
Input Voltage: DC10-32V Static Current: not more than50uA (DC 24V) Alarm Current: 60mA (DV 24V) Operating Temperature: 0 Celsius- +80 Celsius Alarm Reset: Auto reset Wiring Mode: Non polarized, 4-wire Alarm Temperature: Fixed Temp.: 57 Celsius/137F Rate-of-rise: 8-15 ...