Local Call Alarm Phone System

Instruction Steps 1. System Encoding
  • Please note that the alarm phone system and its wireless inductive detectors are required to be encoded before operation. This process is necessary for the linkage to take place between the detector and the alarm phone system. Our company has preset the same default code for the detectors, however, it is recommended to change the default code to a personal code before using the alarm phone system.
  • Encoding Method:
    Alarm Phone Encoding: Open the DIP switch cover located at the back of the alarm phone and you will see an eight-hole DIP switch with switches that are adjustable in up, middle and down positions. Adjust the switches to a position that you desire but keep in mind that the adjusted positions are the set code for the alarm phone system.                                                                                                        Sensor Encoding: Open the switch covers located at the backs of all sensors. Similarly, you will see an identical eight-hole DIP switch. Moreover, adjust each sensor switch to the same encoding position to that of the alarm phone. 2. Security Zone Setup
  • Our alarm phone system has the ability to set multiple independent security zones. (e.g., you can set the front and back balconies as No. 1 security zone, living room and dinning room as No. 2, and bedroom as No. 3 or 4). Thus, this feature enables the alarm system to inform you of exactly which security zone has been breached.
  • Security Zone Setting:                                                                                                  Please open the sensors and  you will find a four-hole DIP switch with switches adjustable in upwards (stands for position 1) and downwards (stands for position 0) position. Follow the illustration of security zone setting and adjust the switches to the same security zone position.
    Attention: this system can set up to 16 security zones altogether, but five of them are preserved for special uses, thus you can set from No. 1 to No. 11 security zones.
    Switch Diagram for Security Zone Setup The diagram above represents security zone being set to No.1 (1 0 0 0 in the figure)
Illustration of Security Zone Setting
Switches 1 2 3 4Switches 1 2 3 4
No. 1 security zone 1 0 0 0 No. 9 security zone 1 0 0 1
No. 2 security zone 0 1 0 0 No. 10 security zone 0 1 0 1
No. 3 security zone 1 1 0 0 No. 11 security zone 1 1 0 1
No. 4 security zone 0 0 1 0 Door detection 0 0 1 1 (Factory preset)
No. 5 security zone 1 0 1 0 Fog detection 1 0 1 1 (Factory preset)
No. 6 security zone 0 1 1 0 Gas detection 0 1 1 1 (Factory preset)
No. 7 security zone 1 1 1 0 Emergency call 1 1 1 1 (Factory preset)
No. 8 security zone 0 0 0 1 Power check 0 0 0 0 (Factory preset)

P11-HS-GSM

  • Country:Taiwan
  • telephone:886-886-2-2795-5799
P11-HS-GSM
*Your name:
*Your Email:
*To:allranges
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...

Addressable fire alarm manual call point for addressable fire alarm system

Instruction manual ofC-6004manual call point 1.Built-in product ID code 2. Using hardware and software filtering to improve the anti-interference ability of the manual call point 3.Use dedicated keys to reset after the chip is pushing down 4. The alarm button provides ...

Come From Shenzhen Puzhesi Technology Co., Ltd.

Conventional Fire Alarm Control System Manual Call Point

Manual Call Point, Designed for Fire Alarm Systems and Security Alarm system. Key Specifications/Special Features Available for flush or surface mounting Plastic film on glass Test key inserted from side Open circuit with series resistor Suitable for the majority of ...

Come From Shenzhen Puzhesi Technology Co., Ltd.

Status Call- 9 Zone Voice alarm system

Two-Way Radio Based 9 Zone Alarm & Safety System ...

Come From Mainserve africa (pty) ltd