not require an external power supply.
has two LED indicators: Polling and Relay Active. The module does
normally open or normally closed. The module is loop-powered and
contacts with max. load of 8 A 250 VAC. The relay can operate as
configuration.The module has one relay output with volt-free, unipolar
lifts, dampers etc. on fire and fault event as defined in cause-effect
The module is used for activation of external equipment such as
MG-6700 Mains Relay Controller, 1-Way Output
and MG-5100 series manual call points is recommended.
For best performance, connecting MG-2000 series fire detectors
The MG-6400 series modules require external 24 VDC power supply.
indicators: Polling and 24 V Fault.
inputs, each having a separate address. The modules have two
The MG-6400 model has one input. The MG-6408 model has 8
modules are continuously monitored for open and short circuits.
and unlimited number of manual call points. Zone circuits of the
with conventional zones, each capable of hosting up to 20 detectors
The modules are used for expanding the fire alarm control system
MG-6408 Zone Monitor, 8-Way Input
MG-6400 Zone Monitor, 1-Way Input
Strobes or 20 MG-5400 Fire Alarm Bells.
Each output can host 16 MG-5000 Sounders, 8 MG-5200 Sounder
The MG-6300 series modules require external 24V DC power supply.
Active, and 24 V Fault.
separate address. The modules have three indicators: Polling, Sounder
one output. The MG-6308 model has 8 outputs, each having a
monitored for open and short circuits. The MG-6300 model has
in cause-effect configuration. Sounder circuit is continuously
fire alarm bells and other audio-visual warning devices as defined
The modules are used for activation of sounders, sounder strobes,
MG-6308 Sounder Controller, 8-Way Output
MG-6300 Sounder Controller, 1-Way Output
powered and have one indicator: Polling.
inputs, each having a separate address. The modules are loop-
open and normally closed contacts. The MG-6208 model has 8
model has one volt free input, which can monitor both normally
devices, control contacts and other security outputs. The MG-6200
sprinkler system, alarm inputs, general purpose fire prevention
The modules are used for monitoring of external devices such as
MG-6208 Switch Monitor, 8-Way Input
MG-6200 Switch Monitor, 1-Way Input
and Relay Active.
The modules are loop-powered and have two indicators: Polling
MG-6108 model has 8 outputs, each having a separate address.
free changeover normally open and normally closed contacts. The
configuration. The MG-6100 model has one relay output with volt
lifts, dampers etc. on fire or fault event as defined in cause-effect
The modules are used for activation of external equipment such as
MG-6108 Relay Controller, 8-Way Output
MG-6100 Relay Controller, 1-Way Output
- 8-way input and output module models
- Power supply fault monitoring by volt-free changeover contact
- Loop-powered Switch Monitors and Relay Controllers
- LED-indicated activation and fault conditions
- Easily programmable by Loop Manager
-"Soft" addressable by use of Address Programmer
- Microprocessor-controlled
Features
CONTROLLER MODULES
HAREZMIC SERIES INTELLIGENT ADDRESSABLE MONITOR AND
VIP (Very Intelligent Protocol) compatible.
SSPB (Russia) certified. Approved by
Kazakhstan, Oman, and Bahrain Civil
Defense
Package: | Ask for details |
Outer color: | White |
Usage: | output devices |
Model Number: | MG-6000 series |
Brand Name: | MaviGard |
Place of Origin: | Turkey |