Wireless Manual Call Point

Radio emitter reads the separate zones of each detector lying at a distance of 85 feet and push the signal which is read by panel. Manual call point can activate radio emitter. So as soon as emitter receives signal from the manual call point siren of 85 db starts and also emitter sends signal to the panel. PS. - ALONG WITH SMOKE DETECTORS THERE IS POSSIBILITY TO INSTALL MAGNETIC SWITCH , PIR SENSORS FOR SECURITY SYSTEM ALSO WITH THE SAME PANELSpecification For Intelligent Wireless Radio Emitter Cum Hooter Description: Wireless Hooter Compatibility: All KARSAN analogue smoke sensors through radio waves Mounting: Plugs into surface base Indication: Alarm 85 db Principle Function: Reads different zones of smoke sensors and push the signals so as to collect and read by wireless panel Operating Voltage: 15 volts DC ( Rechargeable Alkaline batteries) Two pin 5 Amp socket is required to be connected and charging Power Backup: 12 Hours Addressing Method: Unique address embedded in detector Environmental Application: Indoor use Temp Range: 10OC to +70OC Humidity Range: 20% to 95% RH (non condensing) Construction Material: Moulded ABS Colour: White

Wireless Manual Call Point & Emitter With Hooter

  • Country:India
  • telephone:91-91 124 6450170
Wireless Manual Call Point & Emitter With Hooter
*Your name:
*Your Email:
*To:Innovative Engineering & Controls
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...

Explosion Proof Wireless Access Point

Explosion Proof Wireless Access Point Intrinsically safe wireless access point, mode AP198-F, adopted flame-proof type structure, suitable for the site of the explosion of the mixture,like zone 1 and zone 2 flammable gas or vapor and air with IIA and IIB environment and ...

Come From Sichuan Xuxin Technology Co., LTD

Addressable fire alarm manual call point for addressable fire alarm system

Instruction manual ofC-6004manual call point 1.Built-in product ID code 2. Using hardware and software filtering to improve the anti-interference ability of the manual call point 3.Use dedicated keys to reset after the chip is pushing down 4. The alarm button provides ...

Come From Shenzhen Puzhesi Technology Co., Ltd.

Conventional Fire Alarm Control System Manual Call Point

Manual Call Point, Designed for Fire Alarm Systems and Security Alarm system. Key Specifications/Special Features Available for flush or surface mounting Plastic film on glass Test key inserted from side Open circuit with series resistor Suitable for the majority of ...

Come From Shenzhen Puzhesi Technology Co., Ltd.