O2 Alarm

This sensor, like most gas sensors, measures the partial pressure of the oxygen and therefore the reading will vary in proportion to the barometric pressure. The ICA221 will operate continuously and is powered from the mains AC supply.

The high-performance electrochemical oxygen sensor is very stable in operation with an expected life of two years. The calibration will gradually decline during the sensor life and recalibrating with fresh air at 21% will occasionally be required.

The alarm consists of an internal low intensity audio sounder and a contact that can be used to switch an external alarm system.

The ambient atmosphere diffuses into the oxygen sensor which is mounted on the front of the instrument. The output is measured and displayed on the digital controller and the alarm level is set with the control buttons.  The alarm will activate below the setpoint which is typically 19% O2.

The ICA 221 is an oxygen indicator and alarm to monitor the oxygen in the atmosphere surrounding the instrument. It is designed to protect both product and personnel from low ambient oxygen caused by leakage from storage and production plant for nitrogen, carbon dioxide or other asphyxiant gases.

Oxygen Analyser
0.1% O2 Resolution, LED Digital display, High performance Cell, No CO2 interference, Low zero drift

  • Country:United Kingdom
  • telephone:44-1892-831700
Oxygen Analyser
0.1% O2 Resolution, LED Digital display, High performance Cell, No CO2 interference, Low zero drift
*Your name:
*Your Email:
*To:ICA Storage Limited
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...

Ukraine-nitrogen cell KGSQ-low liquid level alarms

In the fields of biological sample storage, medical cold chain transportation, and laboratory research, the normal operation of liquid nitrogen tanks is crucial for the cryogenic storage of biological samples such as cells, embryos, and frozen sperm. However, there are many ...

Come From Henan Tianzhidao Biological Technology Co., Ltd.

Brazil low liquid level alarms KGSQ nitrogen liquid container

In the laboratory, some samples need to be stored at low temperatures, and liquid nitrogen storage tanks are usually used. Its normal operation requires a certain amount of liquid nitrogen in the container to ensure the safety of the samples. However, liquid nitrogen is easily ...

Come From Tianchi Cryogenic Machinery Equipment Manufacturing

SpO2 Monitoring Sensor

APK inc offers a broad portfolio of SpO2 sensors, including both reusable and versions for different applications and Patient categories. The principle of pulse oximetry was developed by Nihon Kohden researcher Takuo Aoyagi in the early 1970s. Pulse oximetry measures blood ...

Come From APK Technology Co., Ltd.