To install the PF284:(it is expected to be installed inside the security system controller panel)
The PF284 has a test button which allows you to activate it whether or not it is connected to an alarm system. The All Lights Off button allows you to turn off anything which has been turned on by the interface.
Set the input switch to A for triggering the interface by a low voltage unit (6-8V AC,DC or audio), or to B for triggering the interface by a dry contact closure. Do not connect 230V to the input terminal!
In mode 3 the PF284 will turn on all lamp modules and wall switch modules set to the same house code as the interface. All lamp modules and wall switch modules will be left in the 'on' state when the alarm is de-activated. Mode 3 is the same as Mode 1 except that the interface does not send the code to turn on modules set to the same unit code setting as the interface.
In mode 2 the PF284 will flash all lights connected to lamp modules or wall switch modules. All lamp and wall switch modules will be left in the 'on' state when the alarm is de-activated but appliance modules set to the same house code as the PF284 will turn off.
In mode 1 the PF284 will turn on all lamp modules and wall switch modules set to its house code and will also turn on any other modules set to its unit code, a stereo connected to an appliance module for example. All lamp modules and wall switch modules are left in the 'on' state when the alarm is de-activated but the module set to the same unit code as the PF284 will turn off.
The PF284 connects to an existing alarm system and turns on lights when the alarm is tripped. It has 3 modes of operation.
PF284 - Powerflash Burglar Alarm Interface (USA)
PF284 - Powerflash Burglar Alarm Interface (USA) |