Alarm Over IP (Aoip) -IP Module

The development trends of technical protection are increasingly becoming Internet-oriented.

IP_SEC (IP Security)
(ip-ac.eu) system eliminates all alarm transmission flaws.
It performs three basic functions:
  • Alarm signal transfer from the alarm control panel at the secured building to the monitoring center over the Internet,
  • Constant control over the connection between the secured building and the monitoring center and
  • Alternative alarm signal transfer over telephone lines and/or GSM (GPRS) networks.

The IP_SEC system consists of two components:

The IP_AC interface (IP Alarm Communicator)is a communication device enabling alarm signal transfer from the alarmcontrol panel over the IP network (ADSL, cable, wireless...) and at thesame time using the possibility of transfer over standard telephonelines and GMS (GPRS) networks as backups.

A receiver unit called IP_REC (IP Receiver)is installed at the monitoring center enabling alarm signal reception,control over the connection to the secured building and communicationwith the operating software the monitoring center.

Transmitting alarm over Internet and backup networks

Once the alarm goes off at the secured building, the IP_AC interface seizes it, reads the CONTACT-IDinformation (additionally it can be adapted to any other alarmprotocol), reformats it into an IP package and sends the package overthe IP network to the monitoring center.

Thesignals received by the Input/Output module (which is connetcted to theIP_AC module) can be handled at the same way as alarm signals.

There is an alarm receiver called IP_RECinstalled in the monitoring center enabling alarm signal reception andcontrol over the connection to the secured building over the Internet.

Data transfer takes about one second and does not exceed 70 bytes, asize which does not slow down the Internet connection at the securedbuilding or ar the monitorting center.
The capacity of a ping coming from the receiver and being send back isa little over 30 bytes which also does not slow down the Internetconnection.

What happens when Internet connection is off?

Ifthe Internet connection at the secured building is disconnected, analarm goes off at the monitoring center. The disconnection is alsodetected by the IP_AC interfacewhich tries to transmit the event over the telephone line or GSM (GPRS)network (secondary transfer can be prioritized - telephone line or GSMnetwork). If the secondary connections are disconnected as well, analarm of general disconnection with the secured building is sent to themonitoring software by the IP_REC receiver.

Whatis the most important is that the monitoring center keeps CONSTANTCONTROL OVER THE OPERATION OF THE INTERNET LINE at the securedbuilding. The receiver and the interface constantly check theirconnection in preset adjustable intervals (pings).

IP alarm communication IP_SEC (IP-ac. eu) system provides alarm transmission and line supervision over the Internet.

  • Usage:Alarm transmission
  • Model Number:IP_AC2.0
  • Brand Name:IP_SEC
  • Place of Origin:Slovenia
  • Country:Slovenia
  • telephone:386-2-6202000
Usage: Alarm transmission
Model Number: IP_AC2.0
Brand Name: IP_SEC
Place of Origin: Slovenia
*Your name:
*Your Email:
*To:Globtel
*Subject:
*Message:
Enter between 20 to 3,000 characters. English only.     Characters Remaining: 0 / 3000
*Enter the secure code shown below Mfrbee security Image      Reload Image

We do inquire for you , please wait ...

Photovoltaic Energy IEC104 Remote Ethernet IO Module

BE190 IEC104 Ethernet IO provides 26 IO board options, including digital input/output, analog input/output, thermocouple and resistance temperature detection, etc., which can be combined into more than 10,000 models to meet a variety of application scenarios, and you can select ...

Come From Beilai Technology Co.,Ltd

Dynamic Environment Monitoring Ethernet SNMP I/O Module

BL197 SNMP Ethernet IO provides 26 IO board options, including digital input/output, analog input/output, thermocouple and resistance temperature detection, etc., which can be combined into more than 10,000 models to meet a variety of application scenarios, and you can select ...

Come From Beilai Technology Co.,Ltd

Industrial IoT IgnitionSCADA Cloud Monitoring MQTT IO Module

BL196 MQTT Ethernet IO provides 26 IO board options, including digital input/output, analog input/output, thermocouple and resistance temperature detection, etc., which can be combined into more than 10,000 models to meet a variety of application scenarios, and you can select ...

Come From Beilai Technology Co.,Ltd

Digital Factory OPC UA MES SCADA Ethernet IO Module

BL195 OPC UA Ethernet IO provides 26 IO board options, including digital input/output, analog input/output, thermocouple and resistance temperature detection, etc., which can be combined into more than 10,000 models to meet a variety of application scenarios, and you can select ...

Come From Beilai Technology Co.,Ltd

Industrial EtherCAT Free Combination Digital and Analog Ethernet IO Module

BL192 EtherCAT Combined IO provides 26 IO board options, including digital input/output, analog input/output, thermocouple and resistance temperature detection, etc., which can be combined into more than 10,000 models to meet a variety of application scenarios, and you can ...

Come From Beilai Technology Co.,Ltd

Industrial PROFINET Ethernet IO Module for Siemens PLC S7-1200/1500

BL191 PROFINET Combined IO provides 26 IO board options, including digital input/output, analog input/output, thermocouple and resistance temperature detection, etc., which can be combined into more than 10,000 models to meet a variety of application scenarios, and you can ...

Come From Beilai Technology Co.,Ltd

4/8/16/24 Digital Input and Output Modbus TCP Ethernet IO Module

BL190 Modbus TCP Combined IO provides 26 IO board options, including digital input/output, analog input/output, thermocouple and resistance temperature detection, etc., which can be combined into more than 10,000 models to meet a variety of application scenarios, and you can ...

Come From Beilai Technology Co.,Ltd

BLIIoT Industrial EtherCAT IO Coupler with DIN/DO/AIN/DO IO Module

BLIIOT EtherCAT I/O system BL212 featuring plug-and-play installation without the need for tools and emphasizing stability as a primary characteristic. It is designed with industrial-grade components and complies with EMC (Electromagnetic Compatibility) and EMI (Electromagnetic ...

Come From Beilai Technology Co.,Ltd

Industrial Automation 32CH Ethernet Modbus TCP Distributed I/O Module

BLIIOT Modbus TCP I/O system BL210 featuring plug-and-play installation without the need for tools and emphasizing stability as a primary characteristic. It is designed with industrial-grade components and complies with EMC (Electromagnetic Compatibility) and EMI ...

Come From Beilai Technology Co.,Ltd

16BITS 4~20MA ANALOG SINGLE-ENDED INPUT AIN IO MODULE SUPPORT RS485 AND ETHERNET

BL190 Modbus TCP Combined IO provides 26 IO board options, including digital input/output, analog input/output, thermocouple and resistance temperature detection, etc., which can be combined into more than 10,000 models to meet a variety of application scenarios, and you can ...

Come From Beilai Technology Co.,Ltd