The MAT100 transmits a periodic test signal to indicate its status and alerts the CMS of service problems, such as low backup battery voltage, hours before the battery needs replacing.
Synthesized VHF units
Compact and easy to install
Serial port for parameter programming on-site by the FTU100 or by PC, using dedicated GUP10 Utility software
Interfaces with any alarm panel for transfer of up to 256 different messages (from a comprehensive list of panels tested by KP engineers)
Programmable periodic test messages
The versatile Radio Alarm Transmitter that will connect to any alarm panel
Digital Encoder Encoding 32 bit words in LARS and LARS I protocol with BCH and parity
Technical Data
Power supply
- Voltage, Vdc
- Current standby, mA
- Current max. (during transmission), mA
10 ~ 15
16
1000
Frequency range (synthesized), MHz
- sub-band L1
- sub-band L
- sub-band M
- sub-band H
- sub-band H1
136 ~ 174
136 ~ 155
155 ~ 174
Modulation
FM, FSK, PMW
Transmitter power output, W
5
Stability, %
The MAT100 is a new generation of advanced and high performance Radio Alarm Transmitter end units,
The MAT100 is a new generation of advanced and high performance Radio Alarm Transmitter end units, |